Page 32 of 102
TVL 351
ISSUE 15
Code-090 SERVICES MAN Installation Hoist Mode / Off Hoist Mode.
The controller is in installation hoist mode. The motor can be run on inspection or emergency electrical control
without the CAN2 car / expansion network plugged in. Turn off after installation
[Service]
Code-091 MEMORY SGL User Upload Fail.
User Upload Fail, The CPU has failed to synchronise the parameter data with the USER settings in EEPROM.
[Fault]
Code-092 MOTION DBL Shaft Encoder Hard Dive Fail / Shaft Encoder Dive OK.
The shaft encoder system has requested a dive 3 times, this has failed to reset the unit's position.
[Breakdown]
Code-093 MEMORY SGL Param Back Up Failed.
Unable to write parameters to backup memory in EEPROM.
[Fault]
Code-094 MEMORY SGL Backup Upload Fail.
Backup Upload Fail, The CPU has failed to upload the parameter data from the BACKUP settings in EEPROM.
[Fault]
Code-095 DOORS DBL Multi Pre Lock Fault / Multi Pre Lock OK.
This event is recorded when the CPU has had 3 Pre Lock Fails. Calls will be cancelled and the lift will be “Out of
Service”, parked doors open. Placing a call will clear the event and cause the doors to try to close again. If another
code 095 is again generated, following a further three unsuccessful attempts to close, the doors will again park
open, but will only respond to car calls.
[Breakdown]
Code-096 MEMORY SGL Parameter Updated.
Parameter successfully written to user EEPROM.
[Information]
Code-097 MEMORY SGL Parameters Restored.
The BACKUP settings in EEPROM have been successfully copied to the USER settings.
[Information]
Code-098 MEMORY SGL Parameters Saved.
Parameters have been successfully saved to backup EEPROM memory
[Information]
Code-099 MEMORY SGL Param Default Fail.
Parameter defaulting has failed. Is card SD1 missing or corrupt? Does the card contain the correct factory
parameter file?
[Fault]
Code-100 MOTION SGL Max Re-Level Count Fail.
Maximum number of re-levels accumulated has been exceeded, check oil temperature if hydraulic and LU/LD
signals.
[Fault]
Code-101 MOTION SGL Multi Re-Level Error.
Multiple re-level fails at a particular floor.
[Fault]
Code-102 MOTION SGL Max YOYO Exceed.
Max re-levels within 10 mins exceeded.
[Fault]
Code-103 MOTION MAN Motor Run Timer Trip / Motor Run Timer Reset.
Motor has been running for excessive time without movement being seen by the shaft encoder. Check for shaft
positioning faults, check car can physically move. Clear fault using button in Solutions menu.
[Breakdown]