Page 37 of 102
TVL 351
ISSUE 15
Code-159 MEMORY SGL Backup Parameters Imported.
The backup data held on card SD1 have been imported into Ethos Two Backup EEPROM.
[Information]
Code-160 CONTROL SGL Parameter Update Failure.
Parameter write to user EEPROM failed. Please try again. Contact TVC if problem persists.
[Fault]
Code-161 CONTROL DBL CAN2 Bus Off / Error Passive / CAN2 Bus On / Bus OK.
The CAN2 Controller (Expansion Module Bus / Car Network) is not transmitting. Check termination resistors are
correct, check baud-rate and wiring.
[Fault]
Code-162 CONTROL DBL CAN2 Duplicate ID / CAN2 Bus OK.
A duplicate id has been received from the CAN2 bus this controller has gone off line.
[Fault]
Code-163 CONTROL SGL SD1 Card Format Fail.
Card SD1 was invalid and has been formatted but the format operation failed. Please insert an alternative card.
[Information]
Code-164 SHAFT ENC. SGL ETSD Card Reset.
ETSD Card µP has reset, check user data for reason.
[Fault]
Code-165 SHAFT ENC. DBL Shaft Encoder Shaft Learn / Shaft Learn Stopped.
Shaft Encoder is on a shaft learn sequence.
[Service]
Code-166 SHAFT ENC. DBL Unusable Shaft Encoder Parameters / Shaft Encoder Parameters OK.
The ETSD parameter version does not match the Ethos Two parameter version. Ensure the Ethos Two control
module and ETSD card have been updated to the latest software version.
[Breakdown]
Code-167 SHAFT ENC. SGL Shaft Encoder No Incremental Pulses.
Shaft Encoder is missing quadrature encoder pulses, Ethos Two is trying to move but not registered a change in
counts.
[Fault]
Code-168 SHAFT ENC. SGL Shaft Encoder Wrong Direction.
Shaft Encoder counts are changing in the wrong direction.
[Fault]
Code-169 MEMORY SGL EEPROM Block Write Fail.
Block write of parameters to EEPROM has failed. Event User data field indicates EEPROM instance.
[Fault]
Code-170 MEMORY SGL Backup Import Fail.
The backup data held on card SD1 has not been copied to Ethos Two. Is card SD1 missing or corrupt? Does the
card contain factory and backup parameter files?
[Fault]
Code-171 SERVICES SGL ADS req message .
The ADS has requested a message not yet defined.
[Fault]
Code-172 SHAFT ENC. SGL Shaft Encoder No ABS Change.
Ethos Two is trying to move but the shaft encoder has not registered change in absolute counts.
[Fault]