Code-216 CONTROL MAN Safety Gear Operated / Safety Gear OK.
The Safety Gear has operated. Possible causes are lift over speed or uncontrolled movement.
[Breakdown]
Code-217 MOTION SGL LU And LD Missing On Stopping.
Lift has stopped and is missing LU and LD input, doors cannot open without 2 proximity signals.
[Fault]
Code-218 MOTION SGL Position Count Error On Stopping.
Lift has stopped and is missing it's internally generated LU or LD vanes, the position count may be incorrect for this
floor.
[Fault]
Code-219 MOTION SGL Valve Fail - Starting.
The valve confirmation input was not received on start-up.
[Fault]
Code-220 MOTION SGL Valve Fail - Moving.
The valve confirmation input has dropped whilst moving.
[Fault]
Code-221 MOTION SGL Valve Fail - Stopping.
The valve confirmation input has failed to drop during stopping.
[Fault]
Code-222 MOTION MAN Valve Confirm Fail / Valve Confirm Reset.
The valve confirmation input has failed and the panel has shut down. Clear fault in toolbox menu.
[Breakdown]
Code-223 MOTION MAN Valve Test Failure / Valve Test Reset.
The lift has moved whilst testing the valves and has been shut down. Clear fault in toolbox menu.
[Breakdown]
Code-224 MOTION MAN Not in Door Zone - A3 / Stopped in Door Zone OK - A3.
The lift stopped out of door zone or lost DZM signal whilst re-levelling or advance door opening. Unintended
movement, this event needs resetting manually.
[Breakdown]
Code-225 SERVICES DBL ADS comms failure / ADS comms OK .
The ADS communications has timed out between itself and the Ethos Two controller.
[Breakdown]
Code-226 MOTION DBL Winter Run Start / Winter Run End.
The lift was moved to prevent seizure during the long dark winter months
[Information]
Code-227 MOTION DBL Dormant Parking / Dormant Parking End.
The lift parked at the bottom floor after a period of idleness to reduce hydraulic pressure.
[Information]
Code-228 MOTION DBL Power Saving On / Power Saving Off.
Lift has entered a power saving shutdown mode. Enter a car call to awaken.
[Information]
Code-229 MOTION DBL Normal Service / Off Normal Service.
Normal Service. Lift is in normal service with no active faults that would prevent service to users
[Information]
Code-230 MOTION DBL Self-Test Start / Self-Test End.
The lift is performing a self test after a defined period of idleness. Parameters can be set to customise operation
[Information]