Page 43 of 102
TVL 351
ISSUE 15
Code-246 CONTROL SGL Snapshot Event.
Snapshot Event has been selected within the solution menu by the user.
[Information]
Code-247 CONTROL DBL MMI Link Failed / MMI Link OK.
Communications to the display board has been lost, check hardware.
[Information]
Code-248 CONTROL SGL JSON Read Write Error.
Note event User Data value then contact TVC Customer Support for assistance.
[Fault]
Code-249 CONTROL MAN Final Limit Operated / Final Limit OK.
The Final Limit has operated. Possible causes are lift overrun or uncontrolled movement.
[Breakdown]
Code-250 MOTION DBL Recall Failure / Recall Failure Restore.
The lift failed to recall. Lift has made 3 attempts to get to the designated recall floor and has not been successful
[Breakdown]
Code-251 CONTROL DBL Hyd Thermal Over/Under Temp / Hyd Thermal OK.
Motor Room temperature sensor has tripped indicating thermal over/under temperature in the motor room.
[Breakdown]
Code-252 MOTION DBL Seek TFR/BFR Limit / Found TFR/BFR Limit.
Position verification required. Was lift lost or power cycled?
[Breakdown]
Code-253 CONTROL DBL Menu Service Active / Menu Service Ended.
A special lift service has been initiated via the touch screen, select Activate Service from the Check-List to turn off.
[Service]
Code-254 SERVICES DBL Valve Test Active / Off Valve Test.
Hydraulic valve test in progress, normally after a dormant park.
[Information]
Code-255 SHAFT ENC. DBL Shaft Encoder DZ Stop Learn / DZ Stop Learn Ended.
Shaft Encoder is on a dz stop learn sequence.
[Service]
Code-256 MOTION DBL Incremental Encoder Wiring Fault / Incremental Encoder Wiring OK.
Wiring fault with incremental encoder (J12), check wiring, encoder supply or ABT and ABS switches.
[Breakdown]
Code-257 CONTROL SGL Check SD1.
SD1 Card should be scanned for potential errors (use the error-checking facility on a Windows PC). The card is
usable but operations are taking longer than normal. SD1 Execution time can be viewed in menu Toolbox->Debug
Screens->Processor Status.
[Information]
Code-258 CONTROL DBL Hydro Anti Creep Return / Hydro Creep - At Bottom Floor.
A fault has requested that the lift be returned to the bottom floor to stop creep whilst the lift is shut down.
[Service]
Code-259 SERVICES DBL Remote Isolation / Off Remote Isolation.
The Lift has been isolated remotely.
[Service]
Code-260 CONTROL DBL Group Call Board Fault / Group Call Boards OK..
A call board is missing from the group bus. Check view I/O screens to determine which board is missing.
[Fault]