Page 44 of 102
TVL 351
ISSUE 15
Code-261 CONTROL MAN Multiple Thermal Over Temp. / Multiple Thermal OK.
Motor Room temperature sensor has tripped over 3 times. Clear fault using button in Solutions menu.
[Breakdown]
Code-262 MOTION SGL Lift Over G Event.
The lift acceleration has exceeded the maximum permissible value.
[Information]
Code-263 DOORS DBL Lock Bypass Active / Lock Bypass Disabled.
Lock Bypass switch is active this will stop normal movement, part of the lock circuit is bridged.
[Service]
Code-264 MOTION DBL Brake Set Test Active / Brake Set Test Finished.
Brake test switch has been operated. Events after this are logged whilst the lift is crash stopped on a single brake at
high speed.
[Service]
Code-265 SHAFT ENC. DBL ETSD Card OKS Monitor Fault / ETSD Card OKS Monitor OK.
The ETSD card has detected that it's OKS output is being kept on by the main CPU, check SW13 on the main CPU.
Both DIPs should be in the OFF position if the ETSD card is fitted
[Breakdown]
Code-266 SHAFT ENC. DBL ETSD Card Pattern Monitor Fault / ETSD Card Pattern Monitor OK.
The ETSD card has detected that it's analogue pattern output is being kept on by the main CPU, check SW13 on
the main CPU. Both DIPs should be in the OFF position if the ETSD card is fitted
[Breakdown]
Code-267 SHAFT ENC. DBL SE Emer. Terminal Slowdown Test / SE ETSD Test Ended.
Shaft Encoder is on an Emergency Terminal Slowdown (ETSD) test sequence.
[Service]
Code-268 CONTROL DBL CAN5 Bus Off / Error Passive / CAN5 Bus On / Bus OK.
The CAN5 Controller on the ETSD Card (Lnd. Net.) is not transmitting. Check termination resistors are correct,
check baud-rate and wiring.
[Fault]
Code-269 SHAFT ENC. DBL SE Param Math Error / SE Param Math Error Ok.
A math error occurred calculating position feedback coefficients. Check encoder settings. Contact TVC if fault
persists.
[Breakdown]
Code-270 SERVICES DBL Car Isolated From Group / Car Back In Group.
Car isolated from group, car is no longer part of the group and will answer it's own landing calls only.
[Information]
Code-271 CONTROL MAN DZ or RDZ Stuck On/Off / DZ and RDZ OK .
Stuck DZ or RDZ input. Door Zone is not switching correctly, check DZ or RDZ input switching and wiring.
[Breakdown]
Code-272 SERVICES DBL On Emer.Elec.Operation / Off Emer.Elec.Operation.
Indicates that the control system is in Emergency Electrical Operation. During this time no calls will be accepted and
all features such as Fire or Service control are disabled.
[Service]
Code-273 SHAFT ENC. SGL Position Recovered.
An abnormal stop was detected and the incremental position has been reset. Abnormal stops may be caused by
mains power or safety circuit interruptions. Check the event log for supplementary events.
[Information]
Code-274 SERVICES DBL On Eng's Access Ctrl / Off Eng's Access Ctr.
Engineer's Access Control. The lift will move to a safe point for the Engineer to access the car top.
[Service]