TVL 351
ISSUE 15
Code-275 SERVICES MAN Jog Motor Screen Active / Off Jog Motor Mode
Indicates that the MMI Jog Motor screen is active. The motor can be moved via the on screen buttons. During this
time no calls will be accepted and all features such as Fire or Service control are disabled..
[Service]
Code-276 SERVICES MAN UPS Shutdown / UPS Shutdown Reset .
UPS Automatic rescue event following lift shutdown. Clear fault using button in Solutions menu.
[Breakdown]
Code-277 CONTROL DBL EMU Log In / EMU Log Out.
The EMU log in button has been set, press again to log out of the EMU. Only applicable if EMU 3 fitted to expansion
bus.
[Information]
Code-278 MOTION MAN iCON SMA Monitor Fail / iCON SMA Monitor OK.
Lift has detected a problem with the iCON SMA monitor unit on starting and has shutdown.
[Breakdown]
Code-279 DOORS SGL Glass Door Sensor Overtime.
If the lift doors are held closed by continuous operation of the glass door edge sensor for more than 20 seconds, the
event is recorded. Check door for obstructions / GDI-RGDI input operation.
[Information]
Code-280 SERVICES DBL Evacuation Service / Off Evacuation Service.
There are two phases to this service - recall and evacuation control. Once lift has recalled to fire floor it will allow
competent persons to evacuate the building before the arrival of Fire Officers. The lift is controlled by holding a car
call down until doors fully closed. Additional car calls can be placed but these will cancel any existing call. Lift will
only exit this service if signal is removed and lift is returned to fire floor and doors opened.
[Service]
Code-281 MEMORY SGL User JSON Import Warning.
The user data held on card SD1 has been successfully imported however one or more parameter values were
incompatible and have been skipped or only partially imported. The event's User Data field gives the number of
detected incompatible parameters; these parameters have been set to factory default values. Check lift operation
before placing into service.
[Fault]
Code-282 MEMORY SGL Backup JSON Import Warning.
The backup data held on card SD1 has been successfully imported however one or more parameter values were
incompatible and have been skipped or only partially imported. The event's User Data field gives the number of
detected incompatible parameters; these parameters have been set to factory default values. Check lift operation
before placing into service.
[Fault]
Code-283 CONTROL DBL CPU Thermal Over Temperature / CPU Thermal OK.
The internal cabinet temperature has exceeded the safe threshold. The panel will not operate until sufficiently
cooled.
[Breakdown]
Code-284 CONTROL SGL CPU Temperature Warning.
The internal cabinet temperature has exceeded the warning threshold. Increase panel cooling.
[Information]
Code-285 CONTROL DBL CAN1 Bus Off / Error Pass. EDir / CAN1 Bus On / Bus OK EDir.
The CAN1 Controller (to E-Director) is not transmitting. Check termination resistors are correct, check baud-rate and
wiring.
[Information]
Code-286 CONTROL SGL Emu3 Remote Login Failure.
It has not been possible to log-in remotely to the Emu3 unit at this time.
[Information]