30
P-43 Sew speed of 3rd stitch 100~5000 1200 spm
P-44 Sew speed of 4th stitch 100~5000 2400 spm
P-45 Sew speed of 5th stitch 100~5000 3600 spm
P-46 Slope adjust for pedal 1~100 30 %
P-47 Reserved - 0 Reserved
P-48 Reserved - 0 Reserved
P-49 Reserved - 0 Reserved
P-50 Reserved - 0 Reserved
P-51 U-disk enable control 0:disable
1:enable
1
P-52 AC voltage warning
enable
0:disable
1:enable
0
P-53 Low end of voltage
warning
150~200 165 volt
P-54 High end of voltage
warnng
240~280 270 volt
P-55 Show current voltage 0~280 220 volt
P-56 Threashold vaule for low
speed stage of pedal
450~650
P-57 Product test switch 0:disable
1:enable
0
P-58 X pos switch when cut 0:disable
1:enable
0
P-59 Up stop position offset for
trimming thread
-120~120 0
P-60 The angle to slow down
on the last work cycle
180~340 315 °
5.2 The Setting of the System Parameters
According to the bellowed steps to set the system parameters:
1) On the normal state(no blinking data on main display),press “Parameter” key to
enter the parameter setting mode.The main display will show “P-01”.
2) Press “+” / “-” key to select parameter item to be changed.
3) Press “Parameter” key to show the current value of this parameter item.
4) Press “+” / “-” key to change parameter value.
5) Press “Set” key to confirm and save the modification to the parameters, or press
“Half stitch motion” key to cancel the modification to the parameters. Either key
pressed will exit the parameter setting mode and return to normal state.