50
Terminal
Parameter
Min. Value
Typical Value
Max. Value
Unit
Digital Output
[COx]
Current*
0
-
100
mA
[COx]
Voltage Goes
0
-
0.5
V
[COx]
Open Drain
0
-
0.1
mA
[COx]
Function
-
NPN(OC)
-
Type
Digital Input
[EIx/SIx/CIx/RIx]
Voltage
0
-
30
V
[EIx/SIx/CIx/RIx]
OFF Area
15
-
30
V
[EIx/SIx/CIx/RIx]
ON Area(low level)
0
-
5
V
[EIx/SIx/CIx/RIx]
Current(0-0.5)
3
-
8
mA
[EIx/SIx/CIx/RIx]
Function
-
-
-
Type
Note: ** For resistive or inductive loads up to 1H.
2.4.2. Dedicated Safety I/O
This section describes the dedicated safety inputs and their
configurations of the safety I/O. Please follow the universal
specifications in Section 2.4.1.
Safety devices and equipment must be installed to comply with the
safety instructions and risk assessment (see Chapter 1).
All safety I/Os exist in pairs (redundancy) and must be kept in two
There is no current protection on the digital output
of the Control Box. If the specified values exceeded,
permanent damage may result.