____________________________________________________________________________________________
Page 52/63 UltraGauge™ EM User Manual www.ultra-gauge.com
Load Default Alarms
MENU Alarms .. Load Default Alarms
Restores all gauge alarm settings back to the factory defaults.
Table 3 - Alarm Factory Defaults
Min Alarm
on/off
Min
Alarm
Value
Max
Alarm
on/off
Max Alarm
Value
Gauge
off 0 off 70
% Engine Load
off 0 on 250
Engine Coolant Temperature
(ºF)
off 0 off 120
Engine Coolant Temperature (ºC)
off 0 off 0
Short Term Fuel Trim Bank 1
off 10
off 10
Long Term Fuel Trim Bank 1
off 0 off 0
Short Term Fuel Trim Bank 2
off 10
off 10
Long Term Fuel Trim Bank 2
off 0 off 50
Fuel Pressure (PSI)
off 0 off 345
Fuel Pressure (kPa)
off 0 off 10
Intake Manifold Absolute Pressure (PSI)
off 0 off 69
Intake Manifold Absolute Pressure (kPa)
off 0 on 4000
RPM
off 0 on 90
MPH
off 0 off 145
KPH
off -30 off 30
iming Advance
º
off 0 on 210
Intake Air Temperature (ºF)
off 0 off 99
Intake Air Temperature (ºC)
off 0 off 400
Mass Air Flow Sensor 1 (g/s)
off 0 off 0
hrottle Position 1
%
abs
off 0.1 off 0.7
Bank 1 Oxygen
Sensor 1 Voltage
off 0.1 off 0.7
Bank 1 Oxygen
Sensor 2 Voltage
off 0.1 off 0.7
Bank 2 Oxygen
Sensor 1 Voltage
off 0.1 off 0.7
Bank 2 Oxygen
Sensor 2 Voltage
off 0 off 500
Miles traveled with Check Engine Light On.
off 0 off 800
Kilometers traveled with Check Engine Light On.
off 0 off 1000
Fuel Pressure (Diesel) (PSI)
off 0 off 690
Fuel Pressure (Diesel) (10kPa)
off 0.8 off 1.2
Bank 1 Wide Oxygen
Sensor 1 Lambda (voltage)
off 0.8 off 1.2
Bank 1 Wide Oxygen
Sensor 2 Lambda (voltage)
off 0.8 off 1.2
Bank 2 Wide Oxygen
Sensor 1 Lambda (voltage)
off 0.8 off 1.2
Bank 2 Wide Oxygen
Sensor
2 Lambda (voltage)
off 0 off 95
EGR % Flow
Cmd
off 0 off 20
EG
% Erro
off 0 off 0
Evaporative Purge %
off 0.1 off 0
Fuel Level % of full
off 0 off 0
Number of Warm-ups since Check Engine Light Cleared
off 0 off 50
Miles traveled since Check Engine Light Cleared
off 0 off 800
Kilometers traveled since Check Engine Light Cleared
off -1 off 1
Evaporative System (PSI)
off -6000 off 6000
Evaporative System (Pa)
off 29
off 30.5
Barometric Pressure –
Inches of Mercury (inHg)
off 98.2 off 103.2
Barometric Pressure –
Inches of Mercury (Pa)
off 0.8 off 1.2
Bank 1 Wide Oxygen
Sensor 1 Lambda (current)
off 0.8 off 1.2
Bank 1 Wide Oxygen
Sensor 2 Lambda(current)
off 0.8 off 1.2
Bank 2 Wide Oxygen
Sensor 1 Lambda(current)
off 0.8 off 1.2
Bank 2 Wide Oxygen
Sensor
2 Lambda(current)
off 0 on 2011
Catalytic Converter Bank 1 Sensor 1 Temperature (ºF)
off 0 off 1100
Catalytic Converter Bank 1 Sensor 1 Temperature (ºC)
off 0 on 2021
Catalytic Converter Bank 2 Sensor 1 Temperature (ºF)
off 0 off 1105
Catalytic Converter Bank 2 Sensor 1 Temperature (ºC)
off 0 on 2012
Catalytic Converter Bank 1 Sensor 2 Temperature (ºF)
off 0 off 1100
Catalytic Converter Bank 1 Sensor 2 Temperature (ºC)
off 0 on 2022
Catalytic Converter Bank 2 Sensor 2 Temperature (ºF)
off 0 off 1106
Catalytic Converter Bank 2 Sensor 2 Temperature (ºC)
off 0 on 14.9
ECM Battery Voltage
off 0 off 90
Load absolute %
off .25 off 1.75
AFR commanded ratio
off 0 off 90
hrottle Position %
Rel
on -10 on 115
Outside Ambient Air Temperature (ºF)
on -23 off 46
Outside Ambient Air Temperature (ºC)
off 0 off 90
hrottle Position 2 %
abs
off 0 off 90
Accelerator Pedal Position 1 %
off 0 off 90
Accelerator Pedal Position 2 %
off 0 off 90
hrottle Position %
Cmd
off 0 off 240
Engine Oil Temperature F
off 0 off 115
Engine Oil Temperature C