Easier to Read BCD396T/UBCD396T Digital Scanner Manual
Note: EDACS Wide is the same as EDACS Standard and use a 9600 baud control channel. EDACS Narrow-band systems use a 4800 baud control
channel. See
here at RR for a description of SCAT.
At 'Edit Name' press E/yes. To name the system, see
Entering Text.
Scroll to 'Set Frequencies' and press E/yes.
At 'New Frequency' and press E/yes.
At 'Input Frequency' enter the frequency and press E/yes.
At 'Input LCN' enter the LCN number and press E/yes. See
Finding EDACS LCN Order.
At 'Edit Frequency' press Menu and scroll down to 'New Frequency', then press E/yes. Repeat to program the rest of the trunking frequencies. Press
Scan to exit.
Then see
Editing System Options to customize the system. Then see Creating Groups. Then see Programming Frequencies/IDs to program IDs.
Contents
To Program a new LTR system, press Menu. At 'Program System' press E/yes.
At 'Select System' scroll to 'New System' and press E/yes.
At 'Select Sys Type' scroll to 'LT' and press E/yes. At 'Confirm?' press E/yes.
At 'Edit Name' press E/yes. To name the system, see
Entering Text.
Scroll to 'Set Frequencies' and press E/yes.
At 'New Frequency' and press E/yes.
At 'Input Frequency' enter the frequency and press E/yes.
At 'Input LCN' enter the LCN number and press E/yes. See
Finding LTR LCN Order.
At 'Edit Frequency' press Menu and scroll down to 'New Frequency', then press E/yes. Repeat to program the rest of the trunking frequencies. Press
Scan to exit.
Then see
Editing System Options to customize the system. Then see Creating Groups. Then see Programming Frequencies/IDs to program IDs.
To Edit the System Name, press the Menu button. At 'Program System' press E/yes.
At 'Select System' scroll to the system that you want to assign a name to and press E/yes.
At 'Edit Name' press E/yes. See
Entering Text.
Press Scan to exit.
Contents
To set the Modulation for a Motorola or LTR system, press the Menu button. At 'Program System' press E/yes.
At 'Select System' scroll to the system you want to set the modulation in and press E/yes.
Scroll to 'Set Modulation' and press E/yes.
Scroll to one of three settings and press E/yes.
Auto- the scanner uses the
default modulation for the frequency band.
FM- the scanner uses FM for the frequency band.
NFM- the scanner uses NFM for the frequency band.
Press Menu to exit.
To set the Attenuator for a trunked system: This setting controls whether the attenuator will be on or off for the system. Turn on this setting if you are near strong signal
sources. Attenuation can help reduce interference by about 18 dB. The default setting is off.
While scanning the system, press the Func then E/yes(att).
Or, press Menu. At 'Program System' press E/yes.
At 'Select System' scroll to the system you want to attenuate and press E/yes.
Scroll to 'Set Attenuator' and press E/yes.
Scroll to On or Off and press E/yes.
Press Menu to exit.
http://marksscanners.com/396/396.shtml (17 of 51)8/17/2010 10:11:40 PM