VECTOR3MANUAL
MAN004REV7.2197/20/2017
SKYHOOK RSL
AtraditionalRSLdoesonething.Itpullsthereserveripcordpinautomaticallyafterabreakaway.TheSkyhookRSLdoes
this,andthengoestwostepsfurther.
A. ItautomaticallyreleasestheLeft(nonRSL)riser,iftheright(RSL)riserreleasesprematurelyforanyreason
(CollinsLanyard).(Youwould
notwantyourreservecontaineropenedwithoneriserstillattached,would
you?)
B. Itthenusesyourdepartingmaincanopyasasuperpilotchutetogetyourreservetolinestretchfasterthan
everbefore.Breakaway,tocanopyoutofbagandlinestretchis½ofa
second,dependingonthesizeofyour
reservecanopy.Thisisuptothreetimesfasterthanapilotchutecandoitalone.
Ifyouhaveamaintotalmalfunction,oryou’reAADfires,theSkyhookLanyardautomaticallyreleases,andtherefore
doesnothingtohindernormalreservedeployment.
TheSkyhookRSLSystemhasfourparts:
1. TheRSLLanyard(5/8”blackwebbing)
withasnapshacklethatconnectstoyour
rightmainriser
atoneend,andthe
yellowCollinsLanyardloopattheother.
2. TheWhiteUniversalLanyardisattached
totheRSLloopwiththereserveripcord
pinattheother.
3. TheRedSkyhookLanyardisalsoattached
totheRSLloop,withtheSkyhook
attachmentloopatits
freeend.
4. TheSkyhookitself,whichissewntothe
reservepilotchutebridle.(BecausetheRSLLanyard,Collin’sLanyard,andSkyhookLanyardareallpartofone
integratedsystem,pullingtheyellowtabontheRSLsnapshackleinactivatesallthree).
