VECTOR3MANUAL
MAN004REV7.2917/20/2017
APPENDIX E: INSTALLING AN OLD-STYLE RESERVE LANYARD (RESERVE STATIC
LINE OR RSL) (NO SKYHOOK)
1.InspecttheRSL:Checkthatthestainlesssteelsnapshackleisoperatingsmoothlyandthatthespringwillretainthe
lockingpin.Checkthatthehookandloopfasteneriscleanandsufficientlytackytoholdthereservelanyardinplace.
Thepinshouldbecurvedfromtheeye
tohalfwaydownitslength.Therestofthepinshouldbestraight.
2.StartbyroutingtheRSLalongitshookand
loopfastenerpathalongsidetherighthandriser.
InsertthepinendoftheRSLthroughtheguide
ringonthe#6topreserveflap.Mate
thepatch
ofyellowpilehookandloopfasteneronthetop
reserveflap.
3.Afterthreadingthereserveripcordthrough
thehousingandplacingtheripcordhandleinto
itspocket,inserttheRSLpinthroughtheloopat
theendofthereserveripcordcable.
4.Placethe
rigonacleansurfacefacingupand
walkonitwithstock ingfeetorcleanshoesto
helpexpelairfromthecontainerandtomakeit
flatter.
5.Replacethetemporarypinwiththereserve
pin.
NOTE
RSLsshouldonlybeinstalledbyaqualified
rigger.