All rights reserved 134 Service Manual e-Series (EN) 1.1.8
C330A
Injection Molding Machine Interface IMMI IO
C330A1
Injection-Molding-Machine-Interface E-Stop
output readback does not match the produced
value
First byte: produced value, second byte: read
value
Check E-stop output
C330A2
Injection-Molding-Machine-Interface Moulding
Area Free output readback does not match the
produced value
First byte: produced value, second byte: read
value
Check output
C330A3
Injection-Molding-Machine-Interface 24V IO
voltage outside acceptable range
The voltage measured on the 24V IO rail is
lower than expected
a) Check the fuses on the Injection-Molding-Machine-Interface
b) Verify there are no short circuits on the 24V IO connectors
c) Contact your local Universal Robots service provider for assistance
C330A4
Injection-Molding-Machine-Interface 48V
voltages outside acceptable range
The voltages measured on the 48V rails are
lower than expected
a) Check the fuses on the Injection-Molding-Machine-Interface
b) Verify there are no short circuits on the IO connectors
c) Contact your local Universal Robots service provider for assistance
C331A
Friction model
C331A0
Critical error
A critical error occurred in the friction model
module
a) Conduct a complete rebooting sequence
b) Update software
c) Contact your local Universal Robots service provider for assistance
C332A
Servo configuration
C332A0
Critical error on Servo configuration
A critical error occurred in the servo
configuration module
a) Conduct a complete rebooting sequence
b) Update software
c) Contact your local Universal Robots service provider for assistance
C400A
Protective Stop: Elbow position close to safety
plane limits
C401A
Protective Stop: Exceeding user safety settings
for stopping time
C402A
Protective Stop: Exceeding user safety settings
for stopping distance
C403A
Protective Stop: Danger of clamping between
the Robots lower arm and tool
C404A
Unexpected behavior
C404A0
Runtime sends data too often
C404A1
Runtime tries to receive data too often
C450A
Force-Torque sensor

Table of Contents

Other manuals for Universal Robots E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Universal Robots E Series and is the answer not in the manual?

Universal Robots E Series Specifications

General IconGeneral
BrandUniversal Robots
ModelE Series
CategoryRobotics
LanguageEnglish

Related product manuals