2.1.4 When the day is fully programmed, the
software exits to the settings menu.
2.1.5 Repeat from step 1 if more days are to be
programmed.
Full week programming:
2.1.1 Press and hold the OK button until the hours
appear.
2.1.2 The hours starts flashing. Use buttons - or
+ to set an interval for Comfort/ECO mode.
Icons in the display show which mode is
activated:
= Comfort mode
= ECO mode
Press OK to confirm each setting except
when marker, at the bottom of the screen,
reaches end of day, which will confirm the
interval.
2.1.3 When the day is fully programmed, the next
day icon starts flashing and the text Copy
Yes appears. (Yes is flashing).
2.1.4 Select Yes to copy the setting of the current
day to the next.
Select No to create a new scheduling interval
for the following day.
2.1.5 Repeat steps 2.1.2 through 2.1.4 until all
available days are programmed.
2.1.6 Press OK to confirm the change and return to
the settings menu.
02 Heating/cooling changeover
In this menu it is manually set whether the system is
in heating, cooling or slave mode. In slave mode, an
external signal decides when to switch to cooling.
To change this setting:
1. Press OK and the parameter starts flashing.
2. Use buttons - or + to change the setting, see list
below.
H = Heating (heating demand icon flashes)
C = Cooling (cooling demand icon flashes)
S = No function, uses heating setting
3. Press OK to confirm the change and return to the
settings menu.
03 ECO mode setback temperature
In this menu the setback temperature for whenever the
channel is in ECO mode is set.
The setting adjusts the current setpoint with the set
value. In heating mode the setpoint is reduced, and in
cooling mode it is increased.
If the setback temperature is set to 0, the thermostat
will remain unaffected if a program sets the system in
ECO mode.
To change this setting:
1. Press OK and the parameter starts flashing.
2. Use buttons - or + to change the parameter.
Default: 4 ˚C
Setting range: 0 – 11 ˚C, 0.5 ˚C increments
3. Press OK to confirm the change and to return to
the settings menu.
04 Control mode
In this menu, control mode for the thermostat is set.
If an external sensor is connected to the thermostat, a
control mode must be chosen to accommodate the extra
functionality of the sensor.
Current control mode is displayed (RT, RFT, RS or RO).
To change this setting:
1. Press OK and the parameter starts flashing.
2. Use buttons - or + to change control mode (see list
below).
RT = Room temperature
RFT = Room temperature with external floor sensor
(limitations does not affect the operation
of the Move PLUS controller, when not
integrated to a Wave/Wave PLUS/Space/
Space PLUS controller)
RS = Remote sensor
RO = Room temperature with remote outdoor
sensor
3. Press OK to confirm the change and return to the
settings menu.
UK
CZ
DE
DK
EE
ES
FI
FR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SK
64
UPONOR SMATRIX MOVE/MOVE PLUS · INSTALLATION AND OPERATION MANUAL

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Uponor SmatrixMove and is the answer not in the manual?

Uponor SmatrixMove Specifications

General IconGeneral
BrandUponor
ModelSmatrixMove
CategoryTemperature Controller
LanguageEnglish

Related product manuals