01 | 2011
INDOOR CLIMATE
UPONOR CONTROL SYSTEM
WIRED
Installation and Operation Manual

Table of Contents

Questions and Answers

  • A
    adkinsannetteSep 3, 2025
    Why isn't the actuator indicator window turning white on my Uponor Temperature Controller?
    • S
      shepardleslieSep 4, 2025
      If the indicator window on the actuator of your Uponor Temperature Controller does not turn white, it could mean the actuator isn't opening. You can try replacing the actuator. Additionally, check that the controller output provides +24 V DC during a heating demand.
  • J
    jessicasmithSep 18, 2025
    Why won't my Uponor thermostat T-38 follow the Z1 or Z2 timing schedule?
    • M
      Mary ScottSep 18, 2025
      For the Uponor Thermostat T-38 to follow the Timer I-36 time schedule, the programming must be turned OFF as described in section 9.7, page 28.
  • G
    garnermarkSep 16, 2025
    What to do if the sensor is missing from Uponor Temperature Controller?
    • D
      Daniel NunezSep 16, 2025
      If the sensor is missing from your Uponor Temperature Controller, reconnect the sensor or connect a missing sensor.
  • B
    Brian CarlsonSep 14, 2025
    Why does the temperature on my Uponor thermostat drop after moving it?
    • L
      Lisa CrawfordSep 14, 2025
      If the temperature displayed on your Uponor thermostat drops after it's moved, it may be influenced by an external heat source. Try changing the location of the thermostat to avoid this.
  • S
    Samantha BarronSep 13, 2025
    What to do if room is heated by another heat source with Uponor UponorControl System Temperature Controller?
    • L
      Lucas HannaSep 13, 2025
      If a room is being heated by another heat source, it may affect the accuracy of the Uponor Temperature Controller. Try changing the thermostat position to a location less influenced by the other heat source.
  • D
    Dr. Nicholas GloverSep 12, 2025
    Why is nothing displayed on my Uponor Digital thermostat or Timer screen?
    • V
      Vincent WilsonSep 12, 2025
      If nothing is displayed on your Uponor Digital Thermostat or Uponor Timer screen, it could be because the back plate has been deformed or bent during installation, preventing power from reaching the thermostat. Try loosening the screws on the wall plate to ensure the thermostat’s back part is not deformed, then reinstall the front part and check for power-up after a few seconds.
  • C
    Christian Boyle IVSep 9, 2025
    Why is an asterisk blinking on my Uponor device screen?
    • T
      Taylor BartlettSep 9, 2025
      If an asterisk is blinking on the screen of your Uponor device, it indicates a short circuit in the sensor connection or a missing sensor. Try replacing the thermostat cable to resolve this issue.
  • P
    pgrantSep 7, 2025
    How to turn off ECO mode on Uponor Timer?
    • D
      David AlvaradoSep 7, 2025
      If ECO mode is displayed on your Uponor timer, it means the system is in energy-saving mode. You can change the ECO profile, assign another profile to the room, or cancel the remaining ECO period by pressing a thermostat key.
  • J
    jordan64Sep 5, 2025
    How to turn off ECO mode on Uponor Thermostat?
    • T
      Thomas SmithSep 6, 2025
      If ECO mode is displayed on your Uponor thermostat, it means the system is in energy-saving mode. You can change the ECO profile, assign another profile to the room, or cancel the remaining ECO period by pressing a thermostat key.
  • D
    dhernandezAug 20, 2025
    How to fix uneven heating with Uponor Temperature Controller?
    • A
      Andrea WardAug 20, 2025
      If you're experiencing uneven heating in your house with the Uponor Temperature Controller, it could be due to zones assigned to loops, actuators, and thermostats not corresponding correctly. Here's what you can do: * Check that loops are assigned to the correct zones. * Verify that the actuators are connected to the same zone in the controller as on the manifold. * Ensure that the thermostats are connected to the correct zone in the controller.

Summary

Copyright and Disclaimer

Preface

Safety instructions

Essential safety precautions for installation and operation.

Disposal

Guidelines for environmentally sound disposal of system components.

Description

System overview

General description of the Uponor Control System Wired.

Example of a system

Illustrates a typical system configuration with components.

Uponor Control System Wired components

Detailed listing and description of system components.

Function

Explains the operational principles and modes of the system.

Installing the Uponor Control System Wired

Preparing the installation

Steps to take before commencing the installation process.

Installing Uponor Controller C-33 and Uponor Controller C-35

Guidance on mounting the main control units.

Connecting components to controller

Instructions for wiring thermostats, actuators, and other devices.

Connection examples

Practical examples illustrating various connection configurations.

Connecting the controller to AC power

Final steps to connect the system to the main power supply.

Installing thermostats

Selecting locations for thermostats

Criteria for choosing optimal placement for thermostats.

Installing Uponor Thermostats T-36 and T-38

Installation procedures for digital thermostats T-36 and T-38.

Installing Uponor Thermostat T-34

Installation guide for the flush-mounted analog thermostat T-34.

Installing Uponor Thermostats T-35, T-33, and T-37

Installation details for analog thermostats T-35, T-33, and T-37.

Installing Uponor Timer 1-36 for C-35

Opening Uponor Timer 1-36

Steps to open the timer housing for installation.

Mounting Uponor Timer 1-36

Guide for mounting the timer unit onto a wall or box.

Connecting Timer 1-36 to controller

Instructions for wiring the timer to the main controller.

Connecting an optional dry contact

How to connect external dry contact inputs to the timer.

Finishing installation

Operating Uponor Control System Wired

Principle of operation

Explanation of how the system regulates heating and cooling.

Normal operation without optional timer

How the system functions without timer-based control.

Operation with optional timer

Benefits and use of an optional timer for energy saving.

Setting analog thermostats

Procedures for adjusting temperature setpoints on analog thermostats.

Operating digital thermostats

Screen layout

Overview of icons and characters displayed on the thermostat screen.

Operating buttons

Functions of the OK, + and - buttons for thermostat control.

Power-up

Initial display sequence when the thermostat is powered on.

Run mode

Understanding the information displayed in normal operating mode.

Parameter and mode settings menu

Navigating the main settings menu for thermostat configuration.

CLK - Clock settings (T-38 only)

Setting the date and time on the T-38 digital thermostat.

PRG - Programming (T-38 only)

Configuring comfort and economy modes with programming schedules.

HOL - Holiday mode (T-38 only)

Setting a specific temperature for periods when the house is unoccupied.

MOD - Regulation choices

Selecting the regulation mode for optimal temperature control.

BAL - Balancing mode

Choosing between manual and automatic balancing for the system.

ECO - Economy mode (T-36 only)

Setting the desired setback temperature for economy mode.

T°C - Comfort and economy mode temperatures (T-38 only)

Adjusting comfort and economy temperature setpoints.

CAL - Calibration

Calibrating the thermostat's internal temperature sensor.

OFF - Standby mode

Disabling regulation while still displaying room temperature.

Lock mode

Preventing unintended operation by locking the thermostat buttons.

Menu trees

Visual representation of the thermostat's menu structure.

Operating Uponor Timer 1-36

Screen layout

Overview of icons and characters displayed on the timer screen.

Operating buttons

Functions of the OK, + and - buttons for timer control.

Power-up

Initial display sequence when the timer is powered on.

Run mode

Understanding the information displayed in normal operating mode.

Parameter and mode settings menu

Navigating the timer's settings menu for configuration.

CLK - Clock settings

Setting the date and time on the timer.

PRG - Programming

Configuring comfort and economy modes with programming schedules.

HOL - Holiday mode

Setting a specific temperature for periods of absence.

OFF - Standby mode

Disabling timer operation while retaining clock display.

Lock mode

Preventing unintended operation by locking the timer buttons.

Menu tree

Visual representation of the timer's menu structure.

Maintenance

Manual preventive maintenance

Routine cleaning and care procedures for the system.

Automatic preventive maintenance

Description of the system's automated pump and actuator exercise function.

Corrective maintenance

Procedures for addressing faults and system issues.

Troubleshooting

Guide to diagnosing and resolving common problems and alarms.

Technical data

Uponor UponorControl System Specifications

General IconGeneral
Input Voltage230 V AC
ApplicationUnderfloor heating and cooling systems
DimensionsVaries by model
WeightVaries by model
Storage Temperature-20 °C to +70 °C