UpRight connectors are designed so that connector parts, contacts or electrical cables may be replaced
without replacing the entire connector.
Figure 1-1:
UpRight Connector Kits
M
ALE
C
ONNECTOR
(P
LUG
)
Figure 1-2:
UpRight Male Connector
1. Disconnect the male connector
(plug) from the female connector
(receptacle).
2. Using the flat end of the Removal
Tool (or flat blade screwdriver), pry
the Locking Wedge from the Male
Connector. Care should be taken
that the Sealing Gasket is not dam-
aged during this procedure.
3. Check all parts for damage. Replace
all parts which are damaged or
worn.
4. Replace or re-crimp the wires and
contacts. Refer to Crimping proce-
dure.
F
EMALE
C
ONNECTOR
(R
ECEPTACLE
)
Figure 1-3:
UpRight Female Connector
1. Disconnect the male connector (plug)
from the female connector (receptacle).
2. Using the notched end of the Removal
Tool (or a wire hook), pull the Locking
Wedge from the Female Connector.
3. Check all parts for damage. Replace all
parts which are damaged or worn.
4. Replace or re-crimp the wires and con-
tacts. Refer to Crimping procedure.
Large KitSmall Kit

Table of Contents

Other manuals for Upright X20W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Upright X20W and is the answer not in the manual?

Upright X20W Specifications

General IconGeneral
BrandUpright
ModelX20W
CategoryLifting Systems
LanguageEnglish

Related product manuals