Page #95 background image
2PS/2PT
1-5-1
1-5 Assemb ly and disassembly
1-5-1 Precautions for assembly and disassembly
(1) Precautions
Be sure to turn the power switch off and disconnect the power plug before starting disassembly.
When handling PWBs (printed wiring boards), do not touch parts with bare hands.
The PWBs are susceptible to static charge.
Do not touch any PWB containing ICs with bare hands or any object prone to static charge.
When removing the hook of the connector, be sure to release the hook.
Take care not to get the cables caught.
To reassemble the parts, use the original screws. If the types and the sizes of screws are not known, refer to
the PARTS LIST.
(2) Drum
Note the following when handling or storing the drum.
When removing the drum unit, never expose the drum surface to strong direct light.
Keep the drum at an ambient temperature between -20°C/-4°F and 40°C/104°F and at a relative humidity not
higher than 85% RH. Avoid abrupt changes in temperature and humidity.
Avoid exposure to any substance which is harmful to or may affect the quality of the drum.
Do not touch the drum surface with any object. Should it be touched by hands or stained with oil, clean it.
(3) Toner
Store the toner container in a cool, dark place.
Avoid direct light and high humidity.

Table of Contents

Other manuals for Utax P-C2660DN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Utax P-C2660DN and is the answer not in the manual?

Utax P-C2660DN Specifications

General IconGeneral
BrandUtax
ModelP-C2660DN
CategoryPrinter
LanguageEnglish

Related product manuals