4
vacon • 10 Commissioning
Tel. +358 (0) 201 2121 • Fax +358 (0)201 212 205
4. COMMISSIONING
The integrated EtherNet/IP protocol in the Vacon 100 drive must be selected when ordering the
drive. If the drive is not equipped with the integrated EtherNet/IP protocol, the EtherNet/IP menus
do not appear and the protocol cannot be used.
EtherNet/IP is configured from panel or with Vacon Live. Settings for EtherNet/IP can be found
under “
I/O and Hardware / Ethernet / EtherNet/IP”.
EtherNet/IP has two menus, one for
parameters and one for monitoring. If the protocol has been disabled, the monitoring menu is not
shown on panel.
In addition to settings below, EtherNet/IP uses common network settings (i.e. IP address, network
mask, etc.).
In the EtherNet/IP master, the configuration assembly for the Vacon 100 drive must be configured
as instance number 103 with a byte size of 0.
Figure 5.Configuration example from Rockwell PLC.
®