PC BOARDS Service Manual M4 - M10
22.10.2001 Page 86
Power Board Layout (CB00042, CB00055, CB00110, CB00111)
A1
C1
C2
C3
C4
C5
C6
C7
C8
C9
C1 0
C11
C12
C1 3
C14
C1 5
C1 6
C17
C18
C1 9
C2 0
C2 1
C22
C2 3
C24
C2 5
C2 6 C2 7
C28
C29
C3 0
C31
C32
C33
C34
C3 5
C36
C37
C38
C39
C40
C4 1
C4 2
C4 3
C4 4
C45
C47
C4 8
C50
C5 2
C53
C5 5
C5 6
C57
C58
C59
C60
C61
C62
C63
C64
C6 5
C66
C6 7
C6 8
C6 9
C70
C71
C7 2
C73
C74
C7 5
C7 6
C77
C78
C79
C8 0
C8 1
C82
C8 3
C8 4
C85
C86
C87
C88
C89
C90
C9 1
C92
C93
C94
C9 5
D1
D2
D3
D4
D5
D6
D7
D8
D9
D1 0
D1 1
D1 2
D1 3
D14
D1 5
D16
D1 7
D1 8
D19
D2 0
D21
D2 2
D2 3
D2 4
D2 5
D2 6
D27
D28
D2 9
D3 0
D3 1
D32
D33
D34
D35
D36
D37
D3 8
D3 9
D40
D4 1
D42
D43
D4 4
D45
D4 6
D47
D4 8
D49
D50
D51
H1
H2
H3
H4
H5
H6
H7
H1 0
H11
H1 2
H15
H19
H2 0
H2 1
K1
K2
K3
Q1
Q2
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
R13
R1 4
R1 5
R16
R1 7
R18
R1 9
R20
R2 1
R2 2
R23
R2 4
R25
R26
R27
R2 8
R29
R3 0
R3 1
R32
R33
R34
R35
R3 6
R37
R3 8
R3 9
R40
R4 1
R4 2
R4 3
R44
R45
R4 6
R4 7
R4 8
R4 9
R5 0
R5 1
R52
R53
R54
R5 5
R56
R5 7
R5 8
R5 9
R6 0
R6 1
R62
R6 3
R6 4
R65
R6 6
R6 7
R6 8
R6 9
R70
R7 1
R72
R7 3
R7 4
R75
R7 6
R7 7
R7 8
R7 9
R80
R81
R8 2
R8 3
R8 4
R8 5
R8 6
R8 7
R8 8
R8 9
R9 0
R9 1
R9 2
R9 3
R9 4
R95
R96
R10 1
R103
R1 0 8
R1 0 9
R1 1 0
R11 1
R1 1 3
R1 1 4
R1 1 5
R116
R1 17
R11 8
R1 1 9
R1 2 1
R122
R123
R12 4
R1 25
R1 26
R1 2 7
R12 8
R1 2 9
R1 3 0
R1 3 1
R13 2
R1 3 3
R134
R135
R136
R13 7
R13 8
R13 9
R140
R14 1
R14 2
R143
R14 4
R14 5
R14 6
R14 7
R14 8
R14 9
R15 0
R151
R15 2
R15 3
R154
R15 5
R15 6
R15 7
R15 8
R15 9
R1 60
R16 1
R1 62
R163
R1 6 4
R16 5
R166
R16 7
R1 6 8
R16 9
R170
R1 7 1
R172
R1 7 3
R174
R1 7 5
R176
R1 7 7
R178
R1 7 9
R1 8 0
R181
R18 2
R183
R1 8 4
R185
R1 86
R1 8 7
R1 8 8
R1 8 9
S1
T1
T2
V1
V2
V3
V4
V5V6
V7
V8
V9
V10
V11
V12V13
V14
V15
V16
V17
V18
V19
V21V22
V23
V24
V25
V26
V27
V28V29
V30
V31
V32
V33
V34
V35
V36
V37
V38
V39
V40
V41
V42
V43
V44V45
V46
V47
V48
V49
V50
V51
V52
V59
V60
V61
V62
V63
V64
X1
X2
X3
X4
X5X6X7
X8
X9
X1 0
X1 1
X1 2
X1 3
X1 4
X1 5
X1 6
X1 7
X1 8
X1 9
X2 0
X21
X2 2
X17 = Temperature sensor
Pin1: DC-
Pin2: Signal from sensor
X2 = Power for cooling fan via
Adapter board
Pin1: 26Vdc
Pin2: DC-
X3 = Power for process interface
Pin1: -12 Vdc
Pin2: GND
Pin3: +12 Vdc
Pin4: +24 Vdc
Gate resistors (Rx, Ry)
Values on table GATE.XLS
X8 = RFI - network & DC input
Pin1: DC+
Pin3: Line phase U
Pin5: Line phase V
Pin7: Line phase W
X19= Control for charging switch
Pin1: Dry contact
Pin2: Dry contact
X18= Control for dynamic braking
chopper
Pin1: Feedback
Pin2: Gate
X9 = Gate U
X11 = Gate V
X13 = Gate W
Pin1: Emitter, lower leg DC-
Pin2: Gate, lower leg +/- 15V
Pin4: Emitter, upper leg
floating
Pin5: Gate, upper leg +/- 15V
X15 = Power supply
Pin1: Current disbalance
Pin2: Gate signal UH (0 / 5V)
Pin3: Charging switch control
Pin4: Phase U status PHU
Pin5: BRKFB
Pin6: Gate signal UL (0 / 5V)
Pin7: BRKDRV
Pin8: Gate signal VH (0 / 5V)
Pin9: TEMP
Pin10: Phase V statusPHV
Pin11: NET
Pin12: Gate signal VL (0 / 5V)
Pin13: UCIN
Pin14: Gate signal WH (0 / 5V)
Pin15: +8V
Pin16: Phase W status PHW
Pin17: +8V
Pin18: Gate signal WL (0 / 5V)
Pin19: DC-
Pin20: DC-
Pin21: DC-
Pin22: DC-
Pin23: -15V
Pin24: -15V
Pin25: +17V
Pin26: +17V
X20 = DC-
X1
Location of fastening screw
X22 = Jumper
DC+ connection to DC busbar