Decommissioning
Installation and maintenance instructions ecoTEC plus 0020116700_01 79
15
15 Decommissioning
15.1 Temporarily shutting down the boiler
b
Caution.
Risk of frost damage due to incorrect
shutdown.
If you switch off the boiler using the on/off
switch or disconnect it from the power
mains, this can cause frost damage to the
heating installation.
> Only shutdown the boiler fully if the
heating installation is otherwise pro-
tected from frost.
> Drain the heating installation fully.
50
1
2
15.1 Switching off the boiler
> Close the gas isolator cock.
> Close the cold water stop valve.
> Drain the heating installation fully
(¬section12.2.2).
> Press the on/off switch (1).
The display (2) goes off.
15.2 Taking the boiler permanently out of
service
> Close the gas isolator cock.
> Close the cold water stop valve.
> Drain the heating installation fully
(¬section12.2.2).
> Press the on/off switch (1).
The display (2) goes off.
> Isolate the boiler from the power mains.
> Dispose of the boiler correctly (¬section 15.3).
15.3 Disposing of the boiler
The Vaillant ecoTEC plus boiler consists primarily of materi-
als that can be recycled.
The boiler and its accessories must not be disposed of with
household waste.
> Make sure that the boiler and any existing accessories
are disposed of properly.