EasyManuals Logo

Vaillant ecoTEC plus SERIES Installation And Maintenance Instructions

Vaillant ecoTEC plus SERIES
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #64 background imageLoading...
Page #64 background image
Inspection and maintenance
64 Installation and maintenance instructions ecoTEC plus 0020116700_01
12
12.4.2 Cleaning the heat exchanger
b
Caution.
Risk of damage from water spray.
If you fail to protect the electronics box
adequately, water can penetrate the box
during cleaning and may damage the elec-
tronics.
> Protect the folded down electronics box
against sprayed water.
> Remove the compact thermal module (¬section12.4.1).
2
3
4
1
12.5 Cleaning the heat exchanger
b
Caution.
Risk of damage to heat exchanger.
> You should neither loosen nor tighten
the four screws (1).
> Clean the heating coil (3) of the heat exchanger (4)
using water or if required commercially-available white
vinegar.
> Allow the vinegar to act on the heat exchanger for 20
minutes.
> Rinse away any loose dirt with a sharp jet of water or
use a plastic brush.
> Do not point the water jet directly at the insulating sur-
face
(2) on the back of the heat exchanger.
The water flows out of the heat exchanger through the con-
densate siphon.
12.4.3 Checking the burner
1
12.6 Checking the burner
As the burner (1) is maintenance-free, it does not require
cleaning.
> Check the surface of the burner for damage.
> If necessary, replace the burner.
12.4.4 Cleaning the condensate siphon
a
Danger!
Risk of death caused by improper main-
tenance.
If you operate the boiler with an empty
condensate siphon, flue gas can escape into
the room air.
> Top up the condensate siphon after each
cleaning session.

Table of Contents

Other manuals for Vaillant ecoTEC plus SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant ecoTEC plus SERIES and is the answer not in the manual?

Vaillant ecoTEC plus SERIES Specifications

General IconGeneral
ModelecoTEC plus SERIES
MountingWall-mounted
Fuel TypeNatural Gas / LPG
ErP Heating Efficiency ClassA
NOx Class5
CategoryBoiler
TypeCondensing
EfficiencyUp to 94%
ErP Water Heating Efficiency ClassA

Related product manuals