CAP. 16 - MESSAGE AND ALARM CODES 68 / 74 ENGLISH
ClimFill Maxi
CODE MESSAGE When it can
occur
Possible
causes
Actions
A033 CIRCUIT LEAKAGE During
vacuum,
vessel filling
or leak test
phase, both
under
pressure
and in
vacuum
Leakage in the
circuit or in the
vehicle fittings.
Identify the leak position
in the vehicle or
connected system and
have it repaired by
trained and qualified
staff according to local
legislation.
A034 VACUUM LEVEL
TOO LOW
During
detection
dye
injection
and oil
injection
phase. The
necessary
vacuum
level is not
been
reached.
Vehicle A/C
system is
pressurised
notwithstandin
g the vacuum
phase,
possible
presence of
leakages
inside A/C
system.
Vacuum
phase time not
sufficient or
phase not
executed
(manual
cycle).
Repeat cycle, increase
vacuum time, if
leakages has been
identified, identify the
leak position in the
vehicle or connected
system and have it
repaired by trained and
qualified staff according
to local legislation.
A035 VESSEL EMPTY During the
gas injection
and flushing
phase
Refrigerant gas
is too low for
the procedure
to be
completed
Fill the internal tank
A036 VESSEL
REFRIGERANT
QUANTITY TOO
LOW
During the
gas injection
and flushing
phase
Gas amount in
internal tank
less than
required
Fill the internal tank