ClimFill Maxi
ENGLISH 67 / 74 CAP. 16 - MESSAGE AND ALARM CODES
Alarm messages are coded Axxx in the window title bar.
Alarms immediately terminate the procedure and prevent its resumption.
CODE MESSAGE When it can
occur
Possible
causes
Actions
A000 EEPROM NOT
WORKING
Electronics
fault
EEPROM
damaged
Replace the logic
electronic board
A001 EEPROM DATA
CORRUPT
Electronics
fault
EEPROM
damaged
Replace the logic
electronic board
A002 PRESSURE SAFETY
SWITCH
ACTIVATED
Pressure
above 18
bar
High pressure
in the internal
tank or circuit
between
compressor
and tank
obstructed or
closed.
Verify
If internal vessel
pressure level is
over 18 bar, wait
for pressure
reduction
disconnect
equipment from
the mains, use
safety protection,
open equipment
and verify if the
valve between
compressor and
internal vessel are
open
A003 ADC NOT
WORKING
Electronics
fault
ADC analog-
digital
converter
damaged
Replace the logic
electronic board.
A032 CIRCUIT STILL
UNDER PRESSURE
During the
vacuum,
vessel filling
or leak test
phase in
vacuum
The vehicle
A/C system is
pressurized
Recover the refrigerant
gas from the vehicle
before starting another
vacuum phase.