INSTALLATION Series
36/116
Edition 2018-08-20 605262EE
The «get-command» is: «i:23xx». The answer returns the data type of a pressure and position signal
«i:23xxy00000». The y value is the current data type of buffer value xx.
Example «get-command» with Terminal: Get the data Type of Position setpoint:
If at start up the data type value in the memory is out of range the default value is taken.
In this case the data type is set to default value (0 = singed integer) and the get
command i:23 add a string “False”:
2. Range of pressure and position values (optional)
The «range of pressure and position values» can be adjusted. That means:
For position values, the value for valve position “CLOSE” and the valve position “OPEN” can be set
to a other ones then the default 0...100’000 is.
For pressure values, the value for physical 0 Volt and 10 Volt of the sensor output can be set to other
values then the default 0...1’000’000 is.
The range of pressure and position values can be configured by ‘Control View’, ‘Control Performance
Analyzer’ or ‘Universal Hyper Terminal’.
The «set-command» is: «s:24xxytoz».
y: lower scale value, floating point, entry with a point ‘.’ and ‘-‘ for negative values possible
z: upper scale value, floating point, entry with a point ‘.’ and ‘-‘ for negative values possible
xx: signal number in the buffer