INSTALLATION Series
64/116
Edition 2018-08-20 605262EE
4.9.1.2 Details
Signal
Type
Name
Byte
Length
Data Type
Valid
Range
Description
Signal
PRESSURE SETPOINT
4
signed integer
(default) or
floating point
0..1’000’00
0
(default),
adjustable
1)
In case of the valve is is pressure mode
(CONTROL MODE = Pressure (5)), the
signal is used as setpoint value.
Signal
POSITION SETPOINT
4
signed integer
(default) or
floating point
0..100’000
(default),
adjustable
1)
In case of the valve is is position mode
(CONTROL MODE = Position (2)), the signal
is used as setpoint value.
min signal value (default 0) = “valve is
closed
3)
”
max signal value (default 100'000) = “valve
is opened”
Signal
CONTROL MODE
SETPOINT
1 unsigned integer 2…7
2 = Position: Position control mode
3 = Close: The valve is closed
2)
4 = Open: The valve is opened
5 = Pressure: Pressure control mode
6 = Hold: Valve is kept in current
position; only valid in CONTROL
MODE position and pressure
7 = Learn: Valve starts the internal learn
procedure
Bitmap
GENERAL CONTROL
SETPOINT
2 boolean array - -
1) To adjust range refer to chapter: «Range of pressure and position values»
2) Valves with isolation functionality (e.g. 650): “Valve is closed” means valve is sealed / isolated. Valves without
isolation functionality (e.g. 612): “Valve is closed” means valve is at the minimum control range position.
3) Valve is moved to minimum control range position but is not isolated/sealed if the valve has a isolation / sealing
functionality (e.g. series 650).