EasyManua.ls Logo

Velleman Personal Scope HPS50 - Operating Mode Selection; Auto Power-off Configuration

Velleman Personal Scope HPS50
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
HPS50 PersonalScope
TM
Fig 18a
2 1
Setup
1. Operating mode :
Scope: normal operation mode.
Demo: Scope goes into demo mode; several ani-
mated screens are displayed one after the other.
Y-cal. calibrate the centre of the signal; only if the
Y position is incorrect during Auto set-up mode.
Help: display of the version number and a short note
on the trigger settings and memory use
(fig. 18b).
NOTE:
Hiding the help screen can only be done by long
keypressing of the ‘Setup’-key and choosing a diffe-
rent operation mode.
Most of the keyboard functions are disabled.
NOTE:
Before power-off, the scope holds the last
screen.
The auto power-off timer is factory-set to 15min
at first power-on or after a reset
Selecting a slow time base (equal or slower than
1min/div) will disable the auto power off.
2. Auto power-off mode :
Select the desired off time: 15 minutes, 1 hour or
infinite (no auto power off).
Fig 18b