P-9
Part #1169256 08/2010
Set Point Temperature
Sensor Reading
Degree Setting
Fan Energy Mode
Periodic Defrost Mode
To change the set point temperature:
1. Press Button 4 when the display reads “Refrigeration.”
2. The display will read “Set Point XX” with the current setting displayed.
3. To change the setting press Button 4 and the current set point temperature will begin to fl ash.
4. Press Button 2 or 3 to increase or decrease the set point.
5. Press Button 4 to save changes.
6. Press Button 1 twice to exit and return “Refrigeration” on display.
To display the temperature:
1. Press Button 4 when the display reads “Refrigeration.”
2. Press Button 2 or 3 until the display reads “Sensor Reading.”
3. Press Button 4 and the current temperature will be shown in Fahrenheit or in Celsius.
4. Press Button 1 twice to exit and return the display to “Refrigeration.”
To change the degree scale:
1. Press Button 4 when the display reads “Refrigeration.”
2. Press Button 2 or 3 until the display reads “Degree Setting.”
3. The display will show the current degree scale (Celsius or Fahrenheit).
4. Press Button 4 and the degree scale will begin to fl ash.
5. Press Button 2 or 3 to choose setting.
6. Press Button 4 to save setting.
7. Press Button 1 twice to exit and return the display to “Refrigeration.”
To change the Fan Energy Savings mode:
1. Press Button 4 when the display reads “Refrigeration.”
2. Press Button 2 or 3 until the display reads “Fan.”
3. The display will read “Fan X” with the current setting displayed.
4. To change the setting press Button 4 and the current Fan mode will begin to fl ash.
5. Press Button 2 or 3 to increase or decrease the Fan mode.
6. Press Button 4 to save changes.
7. Press Button 1 twice to exit and return the display to “Refrigeration.”
To change the Periodic Defrost Mode:
1. Press Button 4 when the display reads “Refrigeration.”
2. Press Button 2 or 3 until the display reads “Periodic Defrost.”
3. The display will show it on or off.
4. Press Button 4 and the setting value will fl ash.
5. Press Button 2 or 3 to choose your setting.
Refrigeration:
If ‘Timing Features’ in Confi guration Mode are ‘Off’, you will only have access to the following
features: