> Close the guards around the machine's cutterbar.
> Fit the pin.
Internal inspection
Every season
»Maintenance intervals« page 53
An internal check of the cone is carried out in the following way:
> Remove the pin.
> Open the guards around the machine's cutterbar.
> Use a suitable tool and remove the top cover on the cone on the
right-hand side of the cutterbar.
> Carry out an internal inspection of the cone for dirt.
> Clean the cone, if necessary.
> Fit the top cover on the cone.
Pin
Pin
Top cover