PROGRAMMING
The 8 way dip-switch enables the setting of the device address and the main door panel type selection.
Switch status
Block
Address
With Sw8 = ON
1 2 3 4 Address
ON OFF OFF OFF 1 1..10
OFF ON OFF OFF 2 11..20
ON ON OFF OFF 3 21..30
OFF OFF ON OFF 4 31..40
ON OFF ON OFF 5 41..50
OFF ON ON OFF 6 51..60
ON ON ON OFF 7 61..70
OFF OFF OFF ON 8 71..80
When the block is set to work with a main door panel of tradi-
tional type (Art.4303N), switch 8 on the Art.4303N must be set to
ON (Main entrances only). Each block can have a maximum of 10
apartments and the range of the addresses for each block is limit-
ed depending on the Art.2306N address (i.e. the intercoms/vide-
ophones/relay connected to the block with Art.2306N address 1
have apartment addresses between 1 & 10, block with Art.2306N
address 3 must have apartment addresses between 21 and 30 etc).
Switch status Main door panel type
OFF* Digital main door panel (Art.4302,
Art.4302V, Art.4302R, Art.4302RV)
ON Traditional main door panel (Art.4303)
* On the digital panels connected to the main bus (BUS-M) enable
the “main” mode in the programming menu. When “main” mode is
enabled the user programming requests to enter the block address
in addition to the device (intercom/videophone/relay) address.
CONTROLS
Jumpers J4 and J2 are used to adjust the signal amplication
and the termination of the main BUS (BUS-M).
SPECIFICATION
Housing/Mounting: 9 Module A Type DIN box / DIN Bar or
directly to the wall
Push Buttons: N/A
Programming: By 8 way dip-switch
Controls: Amplication (J4) and termination
(J2) main bus line BUS-M
Power Supply: From specic power supply
Working Temperature: -10 +50°C
J4 BUSM AMPLIFICATION
Position
Amplication
level
Low
Medium
High
J2 BUSM TERMINATION
Position Termination
Disabled
Enabled
Art.2306N Block exchanger