8
VX2300 Digital System - “2 Wire” Audio/Video Door Entry System
VX2300 Digital System - Installation handbook
SIGNALS ON SYSTEM CONNECTION TERMINALS
1
Common terminal for addresses 1..8 (switch 6 = OFF)
or 65..72 (switch 6 = ON)
E
Addresses 5,13,21,29,37,45,53, 61 (switch 6 = OFF)
Addresses 69,77,85,93,101,109,117, 125 (switch 6 = ON)
2
Common terminal for addresses 9..16 (switch 6 = OFF)
or 73..80 (switch 6 = ON)
F
Addresses 6,14,22,30,38,46,54, 62 (switch 6 = OFF)
Addresses 70,78,86,94,102,110,118, 126 (switch 6 = ON)
3
Common terminal for addresses 17..24 (switch 6 = OFF)
or 81..88 (switch 6 = ON)
G
Addresses 7,15,23,31,39,47,55, 63 (switch 6 = OFF)
Addresses 71,79,87,95,103,111,119, 127 (switch 6 = ON)
4
Common terminal for addresses 25..32 (switch 6 = OFF)
or 89..96 (switch 6 = ON)
H
Addresses 8,16,24,32,40,48,56, 64 (switch 6 = OFF)
Addresses 72,80,88,96,104,112,120, 128 (switch 6 = ON)
5
Common terminal for addresses 33..40 (switch 6 = OFF)
or 97..104 (switch 6 = ON)
BUS
BUS Connection terminals
6
Common terminal for addresses 41..48 (switch 6 = OFF)
or 105..112 (switch 6 = ON)
BUS
7
Common terminal for addresses 49..56 (switch 6 = OFF)
or 113..120 (switch 6 = ON)
PTE Active low input push to exit signal
8
Common terminal for addresses 57..64 (switch 6 = OFF)
or 121..128 (switch 6 = ON)
GND Ground
A
Addresses 1,9,17,25,33,41,49, 57 (switch 6 = OFF)
C Door open relay common contact
Max 12-24
Vac/dc 3A
Addresses 65,73,81,89,97,105,113, 121 (switch 6 = ON)
B
Addresses 2,10,18,26,34,42,50, 58 (switch 6 = OFF)
NC Door open relay normally closed contact
Addresses 66,74,82,90,98,106,114, 122 (switch 6 = ON)
C
Addresses 3,11,19,27,35,43,51, 59 (switch 6 = OFF)
NO Door open relay normally open contact
Addresses 67,75,83,91,99,107,115, 123 (switch 6 = ON)
D
Addresses 4,12,20,28,36,44,52, 60 (switch 6 = OFF)
VAUX
35Vdc power supply input (if used, the module is
powered locally and not from the BUS)
Addresses 68,76,84,92,100,108,116, 124 (switch 6 = ON)
BUTTON MATRIX
The button, when pressed, will generate a call to a specic address according to the terminals to which the button is connected: i.e.
a button connected between terminals “2” and “B, when pressed will generate a call to the address 10 if the dip-switch 6= OFF or a
call to the address 74 if the switch 6=ON.
SW6
OFF
1 2 3 4 5 6 7 8
A 1 9 17 25 33 41 49 57
B 2 10 18 26 34 42 50 58
C 3 11 19 27 35 43 51 59
D 4 12 20 28 36 44 52 60
E 5 13 21 29 37 45 53 61
F 6 14 22 30 38 46 54 62
G 7 15 23 31 39 47 55 63
H 8 16 24 32 40 48 56 64
SW6
ON
1 2 3 4 5 6 7 8
A 65 73 81 89 97 105 113 121
B 66 74 82 90 98 106 114 122
C 67 75 83 91 99 107 115 123
D 68 76 84 92 100 108 116 124
E 69 77 85 93 101 109 117 125
F 70 78 86 94 102 110 118 126
G 71 79 87 95 103 111 119 127
H 72 80 88 96 104 112 120 128