42
Lower Double Oven
The Blower Motor for the lower double oven is
located on the back of the oven cavity. It is used to
reduce air temperature between the oven cavities.
WARNING: Disconnect power to oven
before servicing. Follow lockout/tagout
procedures.
CAUTION: Some areas of the oven
interior are sharp; wear protective gloves to
avoid injury.
Condition Requirements:
Full Access to Control Components
1. Remove 29 screws from the back of the
oven that hold on the back cover.
2. Remove four screws from the blower
motor mounting bracket.
3. Disconnect two connectors from the
blower motor.
4. Remove three screws that attach the
blower motor to the mounting bracket.
5. Reverse procedure for installation.