Diagnostics
Mode B Functions (continued)
Max Ref Run Time Duration
Press “MAX REF” pad. MAX REF” light will glow. One temperature indicator should glow indicating present
Max Ref run time duration in two hour increments. Indicator light one glowing means 4 hours, indicator light 2
glowing means 6 hours, etc. The default duration is 4 hours.
To increase the default Max Ref duration, press “LOWER TEMP” pad to increase duration by two hours.
To decrease the default Max Ref duration, press “HIGHER TEMP” pad to decrease duration by two hours.
The indicator light and corresponding Max Ref run time duration are listed below.
Indicator 1*
23456789
Max Ref Run Time
Duration
4 hrs
6 hrs 8 hrs 10 hrs 12 hrs 14 hrs 16 hrs 18 frs 20 hrs
* Default setting