-  Adding New Devices 
 
[1]  Enter "INSTALLER MODE", select "02:ZONES DEVICES" (see section 5.2) and then select "ADD NEW DEVICE".
 
  Because of encryption, PowerG devices (including Keyfobs) cannot be used on more than one system at one 
time. Remember to verify panel and device compatibility.
 
[2]  See enrollment by button or device ID below. If enrollment is successful, the display reads "DEVICE ENROLLED" 
(or "ID ACCEPTED") and then shows the device details - see [3]. However, if the enrollment fails, the display will 
advise you the reason for failure, for example: "ALREADY ENROLLED" or "NO FREE LOCATION". 
If the enrolled device is adapted to operate as another device that the panel recognizes, the display then reads 
“ADAPTED TO <OK>”.
 
[3]  The display shows the device details and the first available free Zone number for example: "Z01:Motion 
Sensor > ID No. 120-1254" (or "K01:Keyfob / S01:Siren etc. depending on the type of the enrolled device). 
Both Wireless and wired detectors can be enrolled in any zone number. To change the zone number, click the 
 button or type in the zone number, and then press   to confirm. 
 
[4] 
Continue to Part B to configure the device – see diagram below 
How to check Panel 
 Device compatibility 
Each PowerG device bears a 7-character Customer ID printed on the device sticker in the format: FFF-M:DDD, (for 
example, 868-0:012) where FFF is the frequency band and M:DDD is the variant code. For PowerG system devices 
compatibility, make sure the frequency (FFF) band of all devices are the same and that the variant code of the devices 
match the variant code on the panel. 
Enrollment by using Device ID  
The 7-digit Device ID can be used to register a device into the panel locally or from a remote location using the Remote 
Programmer PC software.  The enrollment by device ID is a 2 stage procedure. 
In the 1
st
 stage you register the devices' ID numbers into the panel and complete the device configuration. This can be 
done from a remote location using the Remote Programmer PC software. Following the 1
st
 stage, the PowerMaster 
panel waits for the device to appear on the network in order to complete the enrollment. 
In the 2
nd
 stage, the enrollment is completed when the panel is in full working mode by inserting the battery into the 
device, or by pressing the tamper or enrollment button on the device. This procedure is very useful for adding devices 
to existing systems without the need to provide technicians with the Installer Code, or to allow access to the 
programming menus.  
Remember! The system will indicate a "NOT NETWORKD" trouble until the 2
nd
 stage of all registered devices is 
completed. 
Note: The Soak Test
1
 on pre-enrolled zones can be activated only when the zone is fully enrolled. 
Enrollment by using the Enrollment button  
The panel is set to the Enrollment mode (step #2 above) and the device is enrolled using the Enroll button (refer to the 
device information in the device Installation Instructions, then open the device and identify the Enroll button. For 
keyfobs and keypads, use the AUX '' button. For gas detectors, insert the battery. 
Press the enroll button for 2-5 seconds until the LED turns ON and then release the button. The LED will extinguish or 
may blink for a few more seconds until the enrollment is completed. If enrollment is successfully completed, the 
PowerMaster sounds the "Happy Tune" and the LCD momentarily shows "DEVICE ENROLLED" and then reads the 
device details. 
Enrollment of wired sensors 
To enroll a wired sensor into the wired zone, enter ID: 050-0001 or 050-0002. 
Part B - Configuration 
Step 1