APPENDIX A. Specifications 
76 
D-304762 PowerMaster-10/30 G2 Installer's Guide 
  PowerMaster-10 G2  PowerMaster-30 G2
(2)  7.2V 1300 mAh, rechargeable NiMH 
battery pack, p/n GP130AAH6BMX, 
manufactured by GP only. For UL Listed 
product, use this battery only. 
(3)  9.6V 1800 mAh, rechargeable NiMH 
battery pack, p/n GP180AAH8BMX, 
manufactured by GP or equivalent. 
(4)  9.6V 2200 mAh, rechargeable NiMH 
battery pack (special order) or equivalent. 
Note: Some panel variants use 7.2V 1800 
mAh, rechargeable NiMH battery pack, p/n 
GP180AAH6BMX, manufactured by GP only 
(available by special order).  
Caution! Risk of explosion if battery is 
replaced by an incorrect type. Dispose of 
used batteries according to the 
manufacturer's instructions. 
Note: For compliance with CE standards the 
battery backup period must be at least 12 hours.
 30 Hrs) for all battery types 
Optional Backup 
Battery Pack 
See "Backup Battery Options" above  See "Backup Battery Options" table above 
Time to Charge 
(optional backup 
battery pack) 
80 % (
 24 Hrs) 
NA 
Wired Detectors 
Total (Sum) 
Current 
NA  36* mA max.
Site External Siren 
Current (EXT) 
NA  450* mA max @ 12.5 VDC when powered by 
AC/DC (10.5 VDC when in standby mode)
Site Internal Siren 
Current (INT) 
NA  450* mA max @ 12.5 VDC when powered by 
AC/DC (10.5 VDC when in standby mode)
   
*  
Total PowerMaster-30 G2 output current 
(of INT & EXT sirens, PGM output and 
detectors) cannot exceed 550 mA.
PGM  Current sink to control panel GND 100 mA 
max. 
Max. external DC voltage +30 VDC 
Current sink to control panel GND 100 mA 
max. 
Max. external DC voltage +15 VDC
High Current / 
Short Circuit 
Protection 
NA  All outputs are protected (automatic reset fuse) 
A4. Communication 
  PowerMaster-10 G2  PowerMaster-30 G2
Communication  PSTN; GSM; GPRS; IP (for future use)  PSTN; GSM; GPRS; IP (for future use)
Built-in Modem  300 baud, Bell 103 protocol  300 baud, Bell 103 protocol
Data Transfer to 
Local Computer 
Via RS232 serial port  Via RS232 serial port
Report 
Destinations 
2 Monitoring Stations, 4 private telephones  2 Monitoring Stations, 4 private telephones
Reporting Format 
Options 
SIA, Contact ID, Scancom, SIA IP, Visonic 
PowerNet. 
Note: For UL Listed product, the 
communication formats used are SIA and 
Contact ID. 
SIA, Contact ID, Scancom, SIA IP, Visonic 
PowerNet.
 
Note: For UL Listed product, the 
communication formats used are SIA and 
Contact ID.
Pulse Rate  10, 20, 33 and 40 pps - programmable  10, 20, 33 and 40 pps - programmable
Message to Private 
Phones 
Tone  Tone or voice
Ring Detection  The unit does not support ring detection without 
DC voltage present on the telephone lines. 
The unit does not support ring detection without 
DC voltage present on the telephone lines