5. PROGRAMMING 
58 
D-304762 PowerMaster-10/30 G2 Installer's Guide 
5.9 Diagnostics 
5.9.1 General Guidance – "Diagnostics" Flow-Chart & Menu Options 
The DIAGNOSTICS menu enables you to test your system and to verify proper operation of your PowerMaster panel, 
wireless devices attached to it and the communication (GSM/GPRS/SIM) modules. 
IMPORTANT! Reliable reception must be assured during the initial testing and also throughout subsequent system 
maintenance. A device should not be installed in location where signal strength is "poor". If you get "poor" signal 
strength from a certain device, simply re-locate it and re-test until a "good" or "strong" signal strength is received. This 
principle should be followed throughout the diagnostic test procedure. 
Note: For UL installations, "strong" signal strength for WL devices is required. 
The diagnostic test process is shown below.  
The "07.DIAGNOSTICS" menu contains several sub-menu options, each covering a group of configurable features and 
parameters related to the communication and reporting as follows (see the list in Step 3 of the chart below): 
Option  Description of Option Features and Parameters  Section 
WL DEVICES 
Describes how to test the devices attached to the PowerMaster panel, review 
devices' status and RF signal status. You can test all devices, test single device, 
review devices status and review RF problems, in case of any. 
5.9.2 
GSM/GPRS 
Describes how to test the GSM/GPRS communication module. 
5.9.3 
SIM NUMBER TEST
1
 
Tests the SIM number to ensure correct entry of the SIM number in the control 
panel. 
5.9.4 
BROADBAND 
MODULE
2, 3
 
Contains DHCP Client settings, enables to enter LAN parameters and reset 
broadband module/settings. 
5.9.5 
To enter the "07.DIAGNOSTICS" menu and to select and configure an option, proceed as follows: 
Step 1
 
Unit is OK  
 
 
5.9.5 
5.9.2 Testing Wireless Devices 
The PowerMaster enable to test the wireless devices attached to the panel. You can test all devices, one device at a 
time, display devices' status and review RF problems, in case of any. 
07:DIAGNOSTICS 
 
⋅ ⋅ ⋅ 
 WL DEVICES   
⋅ ⋅ ⋅ 
 MENU you wish   
          
1
 SIM number test is not applicable for UL installations 
2
 
Broadband is not applicable for UL installations
 
3
 The name of the product is PowerLink3 IP Communicator