SPECIAL FUNCTIONS 
20  D-302755 PowerMaxComplete User's Guide 
Important!  If  you  wish  to  exit  the  two-way 
communication  mode  and  execute  another 
command,  just  press  [
]  and  then  key  your  user 
code  followed  by  the  command  (see  “keying 
sequences” in Executable Commands table above). 
Reporting to Private Telephone 
 
The PowerMaxComplete can be programmed by the 
installer  for  selective  transmission  of  messages  to 
private telephone subscribers. Messages are divided 
by type into 4 groups: 
Fire (*), Burglary (**), Panic, Tamper 
Arming AWAY, Arming HOME, Disarming  
No-activity,  Emergency  (***),  Latchkey, 
Gas, Flood, Temperature 
Note:  In  control  panel  with  no-voice  option,  the 
following siren signal will be sent to private telephone 
upon event reporting: 
*  FIRE: ON - ON - ON - pause.... (- - - - - - ......). 
**   BURGLAR: ON continuously ( ...) 
***  EMERGENCY: 2-tone siren; like an ambulance. 
When the called party answers a call initiated by the 
PowerMaxComplete, he will hear a verbal message 
composed  of  the  “house  identity”  and  the  type  of 
event  that  occurred.  For  example,  once  smoke  is 
detected  in  the  Smith  residence,  the  message  will 
be: [The Smith Residence - Fire Alarm]. 
If  a  person  under  surveillance  in  the  Watkins 
residence has been inactive, the message will be: 
[The Watkins Residence - No Activity]. 
The called party must acknowledge the message (as 
explained later on), but if he does not respond, the 
message  will  be  transmitted  repeatedly  as  many 
times  as  possible  within  a  45-second  time  limit. 
When  the  45  seconds  are  up,  the 
PowerMaxComplete will disengage the line and call 
the next private telephone number on its list. 
The called party can acknowledge  the message by 
pressing a key on the telephone keypad, as follows. 
Acknowledge  only:  The 
PowerMaxComplete  disengages  the 
line  and  considers  the  event  duly 
reported. 
Acknowledge  and  listen-in:  The 
protected site is “bugged” for sound for 
50  seconds.  The  called  party  may 
prolong  the  listening  session  by 
pressing  [3]  again  before  the 
PowerMaxComplete  disengages  the 
line, or by pressing [1] to speak. 
Acknowledge  and  speak  out:  The 
called party may speak for 50 seconds 
to whoever is in the protected site. The 
called  party  may  prolong  the  “speak 
out”  session  by  pressing  [1]  again 
before  the  PowerMaxComplete 
disengages the line, or by pressing [3] 
to listen. 
Acknowledge  and  2-way  conversation: 
You and the called party can speak and 
listen without any necessity to switch the 
system  from  "listen-in"  to  "speak-out" 
and vice versa for 50 sec. (extendable). 
Acknowledge  and  request  a  status 
report:  The  PowerMaxComplete  will 
issue a verbal report of system status. 
For example: 
[Disarm - ready to arm] or 
[Disarm - back door open] or 
[Disarm - alarm in memory]. 
Remote Control by SMS 
PowerMaxComplete system with an optional internal 
GSM unit can respond to SMS commands from any 
cellular GSM  telephone,  only  if  the  “REM  ACCESS 
ON”  command  was  pre-selected  by  the  system 
installer. 
The  various  SMS  commands  are  detailed  in  the 
following table (the detailed SMS message sending 
process is described in the cellular  telephone user’s 
guide).  In  this  table,  “<code>”  means  4-digit  user 
code and blank space simply means blank space. 
SMS Command List 
In  the  following  table,  "P#"  is  used  only  for 
PowerMaxComplete with partition enabled - use P1, 
P2, P3, or P4, according to the partition number.