APPENDICES
38 D-302755 PowerMaxComplete User's Guide
Siren
A partition is alarmed when receiving an event from
an alarmed device assigned to that partition.
Alarmed devices do not affect partitions to which
they are not assigned. A siren is common to all
partitions; therefore, an alarm from one or more
partitions will activate the siren.
Siren Activity
The siren will be activated when receiving an
event from an alarmed device.
Overlapping siren activations from different
partitions will not cause the duration of the siren
to be extended.
When the siren sounds, it will not stop until all
alarmed partitions are disarmed. However if the
siren is active due to an alarm from a common
area zone, and one of the partitions assigned to
this area disarms the system, the siren will also
stop. In case that the alarm is initiated from a
common area but continues with zones that are
not assigned to a common area, the siren will
not stop until all partitions assigned to the
alarmed zones are disarmed.
In case that there is a fire in partition 1 and a
burglary in partition 2, the siren will sound FIRE.
When partition 1 is disarmed the siren will
sound BURGLAR for the remainder of the siren
timeout period.
Partition Status display
Partitions status is indicated in the following manner:
P1:X P2:X P3:X
Each X value indicates a different partition state, as follows:
R
Ready
N
Not ready
A
Away
H
Home
E
Exit delay
D
Entry delay
-
Not used
MCT-237
The MCT-237 two-way wireless keyfob is used to
control single or all partitions.
Arming/Disarming All Partitions
To arm/disarm all partitions, press the HOME /
AWAY / DISARM button on the keyfob.
Arming/Disarming a Single Partition
To arm/disarm a single partition, press the
PARTITION SELECTION button on the keyfob once.
In this state repeated pressing of the PARTITION
SELECTION button will toggle between the enabled
partitions and Partition All. To arm/disarm the desired
partition(s), press the HOME/AWAY/DISARM button.
MCT-237
DISPLAY
DISARM
PARTITION
SELECTION
AUX 2
AUX 1
HOME
AWAY

Table of Contents

Other manuals for Visonic PowerMax Complete

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic PowerMax Complete and is the answer not in the manual?

Visonic PowerMax Complete Specifications

General IconGeneral
Operating Temperature0°C to 49°C (32°F to 120°F)
TypeWireless Security System
CommunicationGSM, PSTN, IP
Battery LifeUp to 24 hours
Wireless Range200m (open space)
User Codesup to 8
Event Log250 events
Remote ControlYes
SirenBuilt-in siren
Event ReportingContact ID, SIA
CompatibilityVisonic wireless devices