SPECIAL FUNCTIONS
22 D-302755 PowerMaxComplete User's Guide
Note: During the test period, 24-hour zones will not
cause an alarm if violated, but a fire zone will
function normally.
A typical test will take place as follows:
A. Click
.
The display will read:
WALK TEST
B. Click the button, the display will
prompt you for your user code:
ENTER CODE
_ _ _ _
C. Enter your master user code. The siren will sound
for 2 seconds and the display will change to:
TESTING
D. Walk throughout the protected area and make
sure you trigger every detector with no exception
(move across the field of view of motion
detectors and open/close doors and windows).
Each time a detector is triggered:
The “Happy Tune” will sound,
The zone name and number will be displayed
briefly.
EXAMPLE 1: You triggered a motion detector in
the living room (zone 11). The display will show:
LIVING ROOM
Z11 VIOLATED
After 5 seconds the display will revert to:
TESTING
EXAMPLE 2: You opened a window in partition 3
in the guest room (zone 13). The display will show:
GUEST ROOM
Z13 OPEN
After 5 seconds the display will revert to:
TESTING
E. When done, click the button
repeatedly. The display will show the test results,
partition after partition and zone after zone, in
ascending numerical order. For example:
GUEST ROOM
(alternating)
Z13 OK
or: Z13 NOT OK if there was no response
from Z13.
F. To resume testing, click . To quit the test
mode, click . The display will then read:
<OK> TO EXIT
G. Click . The display will revert to its
normal state.
.

Table of Contents

Other manuals for Visonic PowerMax Complete

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic PowerMax Complete and is the answer not in the manual?

Visonic PowerMax Complete Specifications

General IconGeneral
Operating Temperature0°C to 49°C (32°F to 120°F)
TypeWireless Security System
CommunicationGSM, PSTN, IP
Battery LifeUp to 24 hours
Wireless Range200m (open space)
User Codesup to 8
Event Log250 events
Remote ControlYes
SirenBuilt-in siren
Event ReportingContact ID, SIA
CompatibilityVisonic wireless devices

Related product manuals