6
GIO functions
73
Parameter setting
Use of a warning lamp can be activated and parameterised in tab 7, Air suspension,
Extended ECAS parameters.
Activate the function by clicking on Warning lamp installed. With an LED, click
on parameter as LED (no cable break detection).
– Set the Behaviour upon faults parameter to define whether a fault should only
be indicated after the ignition is switched on or permanently via the fault indica-
tor (warning lamp).
Connecting the components
Extract from diagram 841 802 236 0
Item Component Figure Part number
1 Green warning lamp (LED or bulb)
Assembly on the trailer vehicle into the driver’s
field of vision (above rear mirror).
446 105 523 2
(LED)
2 GIO universal cable
Cable for green warning lamp (Superseal / with
open end)
449 535 ... 0
449 900 100 0
6.3.4 Temporary deactivation of automatic level control
Vehicle type
All trailers with ECAS (integrated in TEBS E).
Purpose
Temporarily deactivating automatic level control while stationary to reduce the air
consumption on the ramp during loading and unloading, for example.
Function
Level control is deactivated when stationary via a switch or via the SmartBoard.
The menu is only visible in the SmartBoard if the function Level control circuit
breaker is activated or eTASC is parameterised.
Actuating the switch or use the ‘Level control off’ menu item in the SmartBoard to
interrupt the adjustment when stationary.