Control 150 M
GB
Preparing the sprayer for longterm storage
1)
Make sure you have already completed the Cleanup
steps on pages 29-30.
2)
Remove the inlet lter. You may need to use a screwdriver
to pry it loose.
Inlet
lter
3)
Pour approximately 60 ml of light household oil into
the inlet valve.
HOUSEHOLD
OIL
4)
Remove hose from outlet valve, place a rag over the
outlet valve, and turn the switch ON. Let the unit run
for ve seconds.
l
5) Switch the pump OFF.
O
6)
Reinstall the inlet lter and press the button on the lter.
Button
7) Wipe the entire unit, hose and gun with a damp cloth to
remove accumulated paint.
8) Replace the high pressure hose to the outlet valve and
replace the hopper lid.
STORAGE
Storage/Conservation of the gun
1)
Unclip the trigger guard from the lter housing by
pulling outward from the lter housing.
2) Unscrew the housing.
3) Turn the gun over and ll with a few drops of oil.
HOUSEHOLD
OIL
4) Reassemble the gun.