EasyManua.ls Logo

WAGNER Super Finish 23i - Startup and Initial Setup; Spray Gun Assembly and Preparation; Technical Specifications

WAGNER Super Finish 23i
108 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
35
Super Finish 23i
DESCRIPTION OF UNIT
3.3 TECHNICAL DATA
Voltage : 230 V AC, 50 Hz
Fuses : 16 A time-lag
Unit connecting line : 6 m long, 3 x 1.5 mm²
Max. current consumption: 7.4 A
Degree of protection : IP 54
Rated input of device: 1.3 kW
Max. operating pressure : 25 MPa (250 bar)
Max. volume ow : 2.6 l/min
Volume ow at 12 MPa
(120 bar) with water : 2.3 l/min
Max. temperature of the
coating material : 43 °C
Max. viscosity : 20,000 mPas
Empty weight
Model including carriage:
Model on frame:
29 kg
24 kg
Hydraulic oil lling
quantity :
Hydraulics housing
Gears
1.15 liter
0.05 liter
Max. vibration at the spraygun : lower than 2.5 m/s²
Max. sound pressure level: 74 dB (A)*
*Place of measurement: 1 m distance from unit and 1.60
m above oor, 12 MPa (120 bar) operating pressure,
reverberant oor
4 STARTUP
4.1 GUN
1. Screw either the whip hose (1 for injection work) or the
nozzle holder with nozzle (2 for spray work) to the gun.
Before any injection work, remove the lter
that is premounted in the gun, as described
below, to prevent it from becoming blocked.
2. Pull the protective bracket (3) forwards.
3. Screw the grip (4) out of the gun housing. Pull out the in-
sertion lter (5).
4. Screw the grip (4) into the gun housing and tighten it.
5. Latch in the protective bracket (3).
3
5
4
1
2

Table of Contents