1.2 Output limitations in gas mode
1.2.1 Output limitations due to methane number
Fig 1-1 Output limitations due to methane number
Calculation Formulas for different compression ratios
if MN 80 and tbax 45 KKNOCK = 1CR 12.7:1
if MN < 80 and/or tbax > 45 KKNOCK = 1 -
0.017*(80 - MN) - (1 - (1 + 0.01*(45 - tbax)))
NOTE
In case of MN <80 and MN >70 derating factor could be 1%/1MN with a
penalization of efficiency.