Troubleshooting
105
MAINDRYER
12:1O.H.THERMOSTAT-INLETAIR
Theerrorcodeisactivatediftheprotectionthermostatforinletairhastriggedduetooverheating.
Theoverheatingthermostatforinletairwillbetriggedat195°C.
Theoverheatingthermostatforinletairneedstobemechanicallyrestored.
Whentheoverheatingthermostatforinletairisrestoreditispossibletoresettheerrorcodefromthe
timerbyashortpressonthecontrolknob/startbuttonandtheongoingprogramwillcontinue.Along
pressonthecontrolknob/startbuttonwillmakethetimerresetandongoingprogramwillbeended.
Theerrorcodecanbetriggedif:
•Theinletairsensorhasstoppedoperatingcorrectly.
•Thefanhasstoppedoperating.
•Theairowisobstructed,bylint,overload,etc.
Iftheoverheatingthermostatforinletairisnottrigged,buttherestillisanerrorcode:
•Checktheharness,connectorsandfunctionsbyreadingtheelectricalschematicandbyusing
theSHOWINPUTSmenuwhenthemachineisinservicemode.
12:2O.H.THERMOSTAT-OUTLETAIR
Theerrorcodeisactivatediftheprotectionthermostatforoutletairhastriggedduetooverheating.
Theoverheatingthermostatforoutletairwillbetriggedat90°C.
Theoverheatingthermostatforoutletairneedstobemechanicallyrestored.
Whentheoverheatingthermostatforoutletairisrestoreditispossibletoresettheerrorcodefrom
thetimerbyashortpressonthecontrolknob/startbuttonandtheongoingprogramwillcontinue.
Alongpressonthecontrolknob/startbuttonwillmakethetimerresetandongoingprogramwill
beended.
Theerrorcodecanbetriggedif:
•Theoutletairsensorhasstoppedoperatingcorrectly.
Iftheoverheatingthermostatforoutletairisnottrigged,butthereisstillanerrorcode:
•Checktheharness,connectorsandfunctionsbyreadingtheelectricalschematicandbyusing
theSHOWINPUTSmenuwhenthemachineisinservicemode.