20
Sensorsandoverheatingthermostats
5Sensorsandoverheatingthermostats
5.1Inletair
5.1.1Overheatingthermostat
Function
Theinletoverheatingthermostatisplacedontheheatingmoduleonthebackofthemachine.
Theinletoverheatingthermostatopensintheeventofoverheatingandshutsoffthemachine.
Resetting
Disconnectthepowertothemachine.
Demounttheupperrearpanel.
Presstheresetbutton(A)ontheoverheatingthermostat.
A
g.W00252
Remounttheupperrearpanel.
Replacementofoverheatingthermostat
Disconnectthepowertothemachine.
Demounttheupperrearpanel.
Disconnecttheoverheatingthermostatandremoveit.Connectthenewoverheatingthermostat.
ElandGasheatedmachine.
Remounttheupperrearpanel.