Sensorsandoverheatingthermostats
25
5.3Vacuumswitch
Function
Thevacuumswitchisplacednexttotheheatingmoduleonthebackofthemachine.
Thevacuumswitchensuresthenecessaryairowinthemachine.
Replacementofvacuumswitch
Disconnectthepowertothemachine.
Demounttheupperrearpanel.
Disconnectthewirestothevacuumswitch.Disconnectthevacuumhose.Notethepositionofthe
wires.
Removethescrews(A)anddisconnectthevacuumswitch.
Connectthenewvacuumswitch.Connectthevacuumhoseandthewires.Makesurethattheart.
No.onthenewvacuumswitchisthesameastheoldone.
A
Remounttheupperrearpanel.