Troubleshooting
12:8CONDENSEWATERCONTAINERISFULL
Thepumpwillrunwhenaprogramstartsfornormally15seconds.Thenitwillrunagainafter
normally3minutes.Thepumpwillalsoruniftheinputfortheoatistrigged.
Theerrorcodeisactivatedifthepumphastriedtoemptythecondensewatercontainerwithoutthe
signalfromtheoatinthecondensewatercontainerhasbeendeactivated.
Whentheoatinthecondensewatercontainerisrestoreditispossibletoresettheerrorcodefrom
thetimer.Theerrorcodeisresetfromthetimerbyashortpressonthecontrolknob/startbutton.
Alongpressonthecontrolknob/startbuttonwillmakethetimerresetandongoingprogramwill
beended.
Theerrorcodecanbetriggedif:
Thecondensewatercontainerisfullandthepumpisnotoperating.
CheckthepumpbyactivatingtheCONDENSERPUMPmenuintheACTIVATEOUTPUTSmenu
whenthemachineisinservicemode.
Ifthepumpisrunningandnowateriscomingout,thedrainisblockedortheoatisoutoforder.
Ifwatercomingoutofthehose,itmightbepartlyblocked.
Ifthepumpdoesnotrunorifthereisnolevelinthecondensewatercontainerchecktheharness,
connectorsandfunctionsbyreadingtheelectricalschematicandbyusingtheSHOWINPUTS
menuwhenthemachineisinservicemode.
12:11DRYINGERRORWITHRMCPROGRAM
TheerrorcodeisactivatediftheRMCsystemdoesnotregisterthattheclothesaredrywithinthe
maximumdryingtime.Whentheerroristriggedthemachinewillautomaticallygotothecooling
modulebeforetheprogramends.
Theerrorcodeisresetfromthetimerbyashortpressonthecontrolknob/startbutton.Alongpress
onthecontrolknob/startbuttonwillmakethetimerresetandongoingprogramwillbeended.
Iftheclothesarestillwetaftermaximumdryingtimeandthedryerisnotoverloaded,checkthatthe
heatingsystemisworkingcorrectbyusingtheACTIVATEOUTPUTSmenuwhenthemachineis
inservicemode.
Note!
Makesurethatthefanisactivebeforeturningontheheat.
Iftheclothesaredry,checktheRMCsystemandharness,connectorsandfunctionsbyreadingthe
electricalschematicandbyusingtheSHOWINPUTSmenuwhenthemachineisinservicemode.
RMCvaluenoload=0%
RMCvalue100KOhmbetweenlifteranddrum=~24%
RMCvaluesystemshortcircuit=50%