Operations Page
The operations page contains three menus:
Active if Input 2 (Input 2 Menu)
is set to [E`In] (event input),
[`EFn] is not set to [none]
and Operations Page Mode
(Lockout Menu) is not set to
[hide].
201 r
[FALS] false (0)
[truE] true (1)
[E`St] Event Input Status
Monitor the event
input status.
Active if Output 4 (Output 4
Menu) is set to [``AL] and
Operations Page Mode (Lockout
Menu) is not set to [hide]
.
114 r
[nonE] (0)
[``Lo] (1)
[``hi] (2)
[AL`4] Alarm 4 Status
Monitor alarm 4
status.
Active if Output 3 (Output 3
Menu) is set to [``AL] and
Operations Page Mode (Lockout
Menu) is not set to [hide]
.
110 r
[nonE] (0)
[``Lo] (1)
[``hi] (2)
[AL`3] Alarm 3 Status
Monitor alarm 3
status.
Active if Output 2 (Output 2
Menu) is set to [``AL] and
Operations Page Mode (Lockout
Menu) is not set to [hide]
.
106 r
[nonE] (0)
[``Lo] (1)
[``hi] (2)
[AL`2] Alarm 2 Status
Monitor alarm 2
status.
Active if Operations Page Mode
(Lockout Menu) is not set to
[hide]
.
319 r
[SAFE] (0)
[``hi] (1)
[``Lo] (2)
[L`St] Limit Status
Monitor the
condition of limit.
Active if Operations Page Mode
(Lockout Menu) is not set to
[hide]
.
100 r
[Pr1`] Process 1
Monitor the process
1 value.
[mon] Monitor Menu
[Oper] Operations Page
[LIM][Mon] Monitor
[LIM] Limit
[Alm] Alarm (if any
alarms are active)
[Oper] Operations Page
Select
Go to an operations
menu.
Display Parameter Range Default Modbus Conditions for
Address Parameters to Appear
read/write
6.4 Parameters Watlow Series 97
Operations Page / Monitor Menu