5
DETAILED PARAMETER DESCRIPTION
✓
NOTE!
This parameter is only visible on the HMI when: P0950 = 1 (Synchronous motor with brushes).
This parameter is only visible on the HMI when: the control type is vector, P0202 = 3 (Sensorless
Vector) or P0202 = 4 (Vector with Encoder).
P0439 - Integration constant of the current regulator IQ
Adjustable range: 0.1 to 999.9 Factory setting: 9.0
Acesso: Menu → Configurations → Control
Description:
Parameter used by the regulator to control the currents.
✓
NOTE!
This parameter is only visible on the HMI when: P0950 = 1 (Synchronous motor with brushes).
This parameter is only visible on the HMI when: the control type is vector, P0202 = 3 (Sensorless
Vector) or P0202 = 4 (Vector with Encoder).
P0440 - Proportional gain of the current regulator ID
Adjustable range: 0.000 to 9.999 Factory setting: 0.074
Acesso: Menu → Configurations → Control
Description:
Parameter used by the regulator to control the currents.
✓
NOTE!
This parameter is only visible on the HMI when: P0950 = 1 (Synchronous motor with brushes).
This parameter is only visible on the HMI when: the control type is vector, P0202 = 3 (Sensorless
Vector) or P0202 = 4 (Vector with Encoder).
P0441 - Integration constant of the current regulator ID
Adjustable range: 0.1 to 999.9 Factory setting: 19.6
Acesso: Menu → Configurations → Control
Description:
Parameter used by the regulator to control the currents.
✓
NOTE!
This parameter is only visible on the HMI when: P0950 = 1 (Synchronous motor with brushes).
This parameter is only visible on the HMI when: the control type is vector, P0202 = 3 (Sensorless
Vector) or P0202 = 4 (Vector with Encoder).
MVW3000 | 5-78