DETAILED PARAMETER DESCRIPTION
Description:
Coefficient of the polynomial of the magnetic saturation curve.
✓
NOTE!
This parameter is only visible on the HMI when: P0950 = 1 (Synchronous motor with brushes).
This parameter is only visible on the HMI when: the control type is vector, P0202 = 3 (Sensorless
Vector) or P0202 = 4 (Vector with Encoder).
P0456 - Coefficient C1 of the Polynomial of the magnetic saturation curve
Adjustable range: 0.000 to 9.999 Factory setting: 1.059
Acesso: Menu → Configurations → Control
Description:
Coefficient of the polynomial of the magnetic saturation curve.
✓
NOTE!
This parameter is only visible on the HMI when: P0950 = 1 (Synchronous motor with brushes).
This parameter is only visible on the HMI when: the control type is vector, P0202 = 3 (Sensorless
Vector) or P0202 = 4 (Vector with Encoder).
P0464 - Maximum compensation current of PF
Adjustable range: 0.00 to 1.00 PU Factory setting: 0.80 PU
Acesso: Menu → Configurations → Control
Description:
Maximum compensation current, in PU, of the power factor.
-P0464
+P0464
i
m
*
+
+
P0119
Δi
f
Power factor control
Figure 5.44: Block diagram of the power factor control
✓
NOTE!
This parameter is only visible on the HMI when: P0950 = 1 (Synchronous motor with brushes).
This parameter is only visible on the HMI when: the control type is vector, P0202 = 3 (Sensorless
Vector) or P0202 = 4 (Vector with Encoder).