7. MAINTENANCE AND CLEANING
7.1 Safety precautions
Carefully read the instructions provided in chapter "I. SAFETY
PRECAUTIONS" on page 33.
7.2 Periodic maintenance
Besides carrying out the maintenance activities ac-
cording to the frequency indicated in the table, must
get a general check by a Qualied Technician at least
once a year.
Component Type of intervention Weekly Monthly Quarterly
GAUGE Keep the boiler pressure between 0,08 and 0,14 MPa (0,8 and 1,4 bar). X
GAUGE
Periodically check water pressure during coee delivery: check the pressure in-
dicated on the gauge, which must be between 0,8 and 0,9 MPa (8 and 9 bar).
X
FILTERS and PORTAFILTERS
Check the condition of the lters. Check for any damage on the edge of
the lters and check whether any coee grounds settle in the coee cup
and replace lters and/or lter holders, as required.
X
GRINDER-DOSER
Check the ground coee dose (between 6 and 7 grams per time); check
the degree of grinding. The grinders must always have sharp cutting
edges. Their deterioration is indicated by the presence of too much
powder in the grounds. We recommend calling the Qualied Technician
to replace the at grinders after every 400/500 kg of coee. For conical
grinders, replace every 800/900 kg.
X
WATER FILTER
SOFTENER
Carry out the water lter cartridge replacement or the water softener
regeneration with frequency specied by the manufacturer.
X
GAS SYSTEM
Check for the presence of possible gas leaks, by spreading a soapy solution
on the pipes.
X
BOILER
Request the intervention of the Technical Assistance at least every three
months to carry out the replacement of the water in the boiler.
X
Problems to the components highlighted in grey require shutting
down the machine and the intervention of the Qualied Technician.
7.3 Maintenance after a brief period of
machine inactivity
"Short machine downtime" refers to a period of time
exceeding one working week.
If the machine is reactivated after this period, the
Qualied Technician must replace all the water contained
in the hydraulic circuits as indicated in par. "7.2 Periodic
maintenance" on page 54.
Furthermore, all operations planned for the periodic
maintenance must be carried out, see previous para-
graph.

Table of Contents

Other manuals for Wega EVD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wega EVD and is the answer not in the manual?

Wega EVD Specifications

General IconGeneral
BrandWega
ModelEVD
CategoryCoffee Maker
LanguageEnglish

Related product manuals